Test And Adjust Oven Burner Flame - Amana ARG7302 Serie Manuel Du Propriétaire

Masquer les pouces Voir aussi pour ARG7302 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Adjusting Air Shutter
1. Remove 4 burner control knobs from range.
• Exposes 2 screws on burner control panel.
2. Remove 2 screws from burner control panel.
• Panel drops slightly after screws are removed.
3. Grasp bottom of burner control panel, gently lift and
pull out panel until clear of burner valve stems.
• After burner control panel clears valve stems,
continue to roll panel until free from range. Set
aside. See Pivot Point in figure.
• Gas valve and orifice hood are visible after burner
control panel is removed.
A
D
A—Burner Control Knob
B—Pivot Point
C—Burner Control Panel
D—Screw
Burner Control Panel
4. Slide air shutter open or closed depending on
appearance of burner flame.
• If flame is yellow and does not hold its shape, open
air shutter.
• If flame is blowing or noisy, close air shutter.
5. Reassemble burner control panel.
Adjusting Air Shutter
B
C
Close
Open

Test and Adjust Oven Burner Flame

Properly adjusted oven burner flames are blue with a
distinct deep blue inner cone approximately ½ inch long.
When using natural gas, flame should not have any yellow
flame when burning. Some yellow flame when burning
LP\propane gas is normal.
Properly Adjusted Flame
Flame should not be visible in the oven cavity when
burning and should not extend into the oven cavity beyond
the removable oven bottom.
Removing Oven Bottom
!
To avoid risk of cuts, wear protective gloves when
removing oven bottom. Sharp edges around oven
bottom can cut.
1. Pull oven bottom forward and lift out.
2. Replace oven bottom.
Burner Area
14
CAUTION
1/2"