4
Electrical installation
Wiring of the feedback system

Digital frequency input/output (encoder simulation)

4.5.3
Digital frequency input/output (encoder simulation)
The digital frequency coupling of ECSxS/P/A axis modules basically is effected
as a master−slave connection via the interface X8. This interface can either be
used as a digital frequency input or as a digital frequency output (e. g. for
encoder simulation) (configuration via C0491).
Features
X8 as digital frequency input
Input frequency: 0 ... 200 kHz
l
Current consumption: max. 6 mA per
l
channel
Two−track with inverse 5 V signals and zero
l
track
Possible input signals:
l
– incremental encoder with two 5 V
complementary signals (TTL encoders)
offset by 90°
The function of the inputs signals can be set
l
via C0427.
138
X8 as digital frequency output
Output frequency: 0 ... 200 kHz
l
Permissible current loading: max. 20 mA per
l
channel
Two−track with inverse 5 V signals (RS422)
l
The function of the output signals can be set
l
via C0540.
l