BFT THALIA Instructions D'installation page 28

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 36
stat
vers
- +
n. cycles
- +
n. remotes
- +
err
0---
password
Diagnostics
code
START E external start input activated
STRE
START I internal start input activated
STRI
OPEN input activated
OPEN
CLOSE input activated
CLS
PED pedestrian input activated
PED
TIMER input activated
TIME
STOP input activated
STOP
Activation of PHOT photocell input or, if configured as verified photocell, Activation
PHOT
of the associated FAULT input
Activation of PHOT OP opening photocell input or, if configured as active verified
PHOP
photocell only when opening, Activation of the associated FAULT input
Activation of PHOT CL closing photocell input or, if configured as active verified
PHCL
photocell only when closing, Activation of the associated FAULT input
Activation of BAR safety edge input or, if configured as verified safety edge, Acti-
BAR
vation of the associated FAULT input
Activation of BAR safety edge input with ACTIVE reversal ONLY WHILE OPENING,
or, if configured as verified safety edge active only while opening, Activation of
baro
the associated FAULT input
Activation of BAR safety edge input with ACTIVE reversal ONLY WHILE CLOSING,
or, if configured as verified safety edge active only while closing, Activation of the
barc
associated FAULT input
The board is standing by to perform a complete opening-closing cycle uninter-
rupted by intermediate stops in order to acquire the torque required for movement.
SET
WARNING! Obstacle detection not active
Photocell test failed
ER01
Safety edge test failed
ER02
Opening photocell test failed
ER03
Closing photocell test failed
ER04
8k2 safety edge test failed
er06
Opening safety edge test failed
ER07
Closing safety edge test failed
ER08
Board hardware test error
ER1x*
Encoder error
ER2x*
Reverse due to obstacle - Amperostop
ER3x*
Thermal cutout
ER4x*
Communication error with remote devices
ER5x*
ER70, ER71
Internal system supervision control error.
ER74, ER75
Consistency error of the control unit's parameters (Logics and Parameters)
ER72
D-track parameter error
ER73
Error during limit switch adjustment
Only for LUX BT E - LUX G BT
Ersw
Error during limit switch adjustment
Only for E5 BT A18 / E5 BT A12
Error in setting the SAFE inputs
ERf3
*X= 0, 1, .., 9, A, B, C, D, E, F
28 -
THALIA
ACCESS MENUS Fig. 1
Control unit software version
OK
bft . . .
+/-
No total manoeuvres (in hundreds)
OK
0000
+/-
No radio control devices memorised
00
OK
+/-
List of last 30 errors
01.33
OK
02.01
........
30.15
+/-
10--
C
= SWC2 motor 2 closing limit
switch input activated
O
= SWO2 motor 2 opening limit
switch input activated
C
= SWC1 motor 1 closing limit
switch input activated
O
= SWO1 motor 1 opening limit
switch input activated
DESCRIPTION
150-
1520
35. 4 0
Instantaneous force motor 2
Instantaneous force motor 1
 
 
 
 
 
 
 
 
 
 
 
 
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or parameter/logic setting
Check photocell connection and/or parameter/logic setting
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
- Check connections to motor
- Hardware problems with board (contact technical assistance)
- Motor or encoder signal power cables inverted/disconnected or incorrect pro-
gramming (see Fig. E)
- Actuator movement is too slow or stopped with respect to programmed operation.
Check fo r obstacles in path
Allow automated device to cool
Check connection with serial-connected accessory devices and/or expansion boards
Try switching the board off and back on again. If the problem persists, contact the
technical assistance department.
Pressing OK the detected settings are confirmed. The board will keep on working
with the detected settings.
The board settings must be checked (Parameters and Logics)
Pressing OK, the board will keep on working with D-track as a default.
An autoset is required
- Repeat the limit switch adjustment procedure.
- Try moving the maximum limits of both the opening and closing limit switches.
- Caution: the last centimetre of the piston's stroke, during either opening or
closing, cannot be used.
- Motor or encoder signal power cables inverted/disconnected or incorrect
programming. (see Fig. E)
Check the setting of the SAFE inputs is correct
 
prg
NOTES