Troubleshooting

Troubleshooting the FastPack
These messages are possible errors that may occur. The FastPack
beep each time an error message is displayed
If a problem persists, please contact your local distributor or call Qualigen, Inc. System Support at 877-
770-6127; or e-mail System Support at systemsupport@qualigeninc.com.
Display  
"Bar Code Failure"  
"Cal Fail"  
"New Lot
Requires Calibration"  
"Time to Re-Calibrate"  
"Calibrator Expired"  
"Close Door"  
"Date Error"  
"Door Failure"  
"Expired Pack"  
65000159   R ev.   0 07   ( 06/15)                                                                                                                                                                                                                                                                                                                                                                                                                               5 7  
IP System Analyzer
®
Cause  
Bar   c ode   r eader   h as   f ailed   o r   d oor   b ar  
code   l abel   i s   o bstructed   o r   d efaced.  
Calibrator   r esult   i s   o utside   o f   t he  
acceptable   r ange.  
Different   l ot   o f   F astPacks   i s   b eing   u sed.  
Time   b etween   c alibrations   h as   e xpired.  
Calibrator   h as   p assed   e xpiration   d ate   o r  
system   d ate   i s   i ncorrect.  
Door   i s   n ot   c ompletely   c losed.  
A   d ate   t hat   i s   n ot   p ossible   h as   b een  
entered.  
•   B ar   c ode   w indow   i nstalled   i ncorrectly.  
•   S ilicone   s hield   i ncorrectly   i nstalled.  
®
•   F astPack
  I P   o r   c ard   h as   s lipped   o ff  
positioning   p in.  
•   D oor   l atch   h as   f ailed.  
®
FastPack
  I P   h as   p assed   e xpiration   d ate  
or   s ystem   d ate   i s   i ncorrect.  
IP System analyzer will sound with a
®
Action  
Check   f or   o bstruction   a nd   t ry   F astPack
IP   o r   c ard   a gain.  
Contact   S ystem   S upport.  
Re-­‐run   a   n ew   c alibrator   s ample   a nd   b e  
certain   t he   F astPack®   I P   h as   a   p roper   f ill.  
If   e rror   p ersists,   p erform   a   C alibration  
Reset,   t hen   r e-­‐calibrate   t he   a nalyzer.  
Use   t he   s ame   F astPack®   l ot   p reviously  
used   o r   r e-­‐calibrate   t he   a nalyzer   f or   t he  
new   l ot   o f   F astPacks.  
Run   c alibration   f or   d esired   a ssay.  
•   V erify   s ystem   d ate   i s   c orrect.  
•   I f   c orrect,   o btain   a   n ew   C alibration   K it.  
Close   D oor.  
Re-­‐enter   c orrect   d ate.  
•   R emove   t he   b ar   c ode   w indow.  
•   V erify   t hat   e dges   o f   s ilicone   s hield   a re  
flush   w ith   b ack   p late.  
•   V erify   t hat   F astPack
correctly   p ositioned.  
•   C ontact   S ystem   S upport.  
•   V erify   s ystem   d ate   i s   c orrect.  
•   I f   c orrect,   o btain   n ew   l ot   o f   F astPack
IP.  
®
 
®
  I P   o r   c ard   i s  
®
 