CONTROL PANEL INSTRUCTIONS

Set temperature
1.
Press
and the set temperature will flash on the display.
2.
Repeatedly press
3.
Press
to exit and the storage temperature is displayed.
NOTE: If no button is pressed within 10 seconds, the storage temperature will be displayed.
Refrigeration indicator light
During refrigeration, this indicator light will illuminate;
When the storage temperature is constant, this indicator light will go out;
During the delay start, this indicator light will flash.
Defrosting indicator light
During defrosting, this indicator light will illuminate;
During the delay start, this indicator light will flash.
Parameter setup
1.
Press and hold
E1 will flash on the display.
2.
Repeatedly press
Parameter
E1
E2
E3
E4
Compressor start delay time
E5
Offset on room temperature
3.
Press
/
If no button is pressed within 10 seconds, it will return to normal operation mode.
/
to modify and store the displayed values.
for about 6 seconds to enter the parameter setup mode.
to select the parameter required.
Function
Lower setpoint limit
Higher setpoint limit
Temperature hysteresis
, the value of parameter will be displayed and can be modified and stored.
Setting range
-50°C ~ Set temperature
Set temperature ~ +99°C
1°C ~ 20°C
0 ~ 10 min.
-10°C ~ 10°C
Default
-20°C
8°C
3°C
0 min.
0°C