5.1 3-digit LED display

During normal operation, the display is off. It is
activated by briefly operating one of the two
pushbuttons
. It is used for displaying
current values and preset parameters. In addition,
the display is used for operator prompting during
programming of operating parameters.
Display
Function
t = TIMER
The control unit operates as a time-
PA = PAUSE
controlled contact maker (TIMER)
and is in the PAUSE mode
c = COUNTER
The control unit operates as a
PA = PAUSE
contact counter (COUNTER)
and is in the PAUSE mode
t = TIMER
The control unit operates as a time-
CO = CONTACT
controlled contact maker (TIMER)
and is in the pump running mode
(CONTACT)
c = COUNTER
The control unit operates as a
CO = CONTACT
contact counter and is in the pump
running mode (CONTACT)
Special application! Not to be
used for KFA / KFAS units
C = Cycle
Display of beginning of menu
O = OFF
„Monitoring settings"
P = Pressure
Page 23
Next
Chapter
5
Operating Instructions KFA, KFAS
Description
Part of lubrication cycle
Entered and displayed value
in hours
Part of lubrication cycle
The device counts the pulses
from an external contact maker
and compares them with the
preset values
CONTACT = time during which
the pump delivers
Entered and displayed value
in minutes
CONTACT = time during which
the pump delivers
Entered and displayed value
in pulses