5.1 3-digit LED display
During normal operation, the display is off. It is
activated by briefly operating one of the two
pushbuttons
. It is used for displaying
current values and preset parameters. In addition,
the display is used for operator prompting during
programming of operating parameters.
Display
Function
t = TIMER
The control unit operates as a time-
PA = PAUSE
controlled contact maker (TIMER)
and is in the PAUSE mode
c = COUNTER
The control unit operates as a
PA = PAUSE
contact counter (COUNTER)
and is in the PAUSE mode
t = TIMER
The control unit operates as a time-
CO = CONTACT
controlled contact maker (TIMER)
and is in the pump running mode
(CONTACT)
c = COUNTER
The control unit operates as a
CO = CONTACT
contact counter and is in the pump
running mode (CONTACT)
Special application! Not to be
used for KFA / KFAS units
C = Cycle
Display of beginning of menu
O = OFF
„Monitoring settings"
P = Pressure
Page 23
Next
Chapter
5
Operating Instructions KFA, KFAS
Description
•
Part of lubrication cycle
Entered and displayed value
in hours
•
Part of lubrication cycle
•
The device counts the pulses
from an external contact maker
and compares them with the
preset values
•
CONTACT = time during which
the pump delivers
•
Entered and displayed value
in minutes
•
CONTACT = time during which
the pump delivers
Entered and displayed value
in pulses