LIMIT SWITCH FITTING
In order to determine the gate travel length, place two cams (Fig. 12) at the ends
of the rack (Fig. 13).
Move the cams on the rack teeth to adjust their opening and closing travel.
To fix the cams to the rack, tighten the screws issued.
Note: In addition to the electric stop cams mentioned above, you must also
install strong mechanical stops preventing the gate from sliding out from the
top guides.
ELECTRICAL CONNECTIONS
To correctly connect the gearmotor to the control unit, follow the table below:
COLOUR
Black
Brown
Grey or light blue
Yellow / green
GROUND CONNECTION
The system must be grounded.
Use the predisposed clamp, connected to the yellow / green cable, to connect
the gearmotor to the ground system.
MAINTENANCE
To be carried out exclusively by skilled persons after the power supply to the
motor has been interrupted.
Periodically, when the gate is standstill, clean and keep the guide free from
stones and dirt.