Télécharger Imprimer la page

Speedaire 35WC74 Instructions D'utilisation Et Manuel De Pièces page 10

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION INSTRUCTIONS
maintenance.
coolers. Do not use unit to lift other attached equipment.
Picking the Location
Install and operate unit at least 18 inches from any obstructions in a
clean, well ventilated area. The surrounding air temperature should
not exceed 100° F. This will ensure an unobstructed flow of air to cool
compressor and allow adequate space for maintenance.
any other source of contamination.
NOTE: If compressor operates in a hot, moist environment, supply
compressor pump with clean, dry outside air. Supply air should be
piped in from external sources.
*
Model shown may not be exact model and is used to demonstrate
need for minimum 18 inch spacing around compressor.
Tank Mounting
The tank should be bolted into a flat, even, concrete floor or on a
separate concrete foundation. Vibration isolators should be used
between the tank leg and the floor. Model 2LVP7 isolator pads are
recommended for units. Isolator pads are included with fully packaged
models.
When using isolator pads, do not draw bolts tight. Allow the pads to
absorb vibrations. When isolators are used, a flexible hose or coupling
should be installed between the tank and service piping.
at the welded joints and possible bursting.
Piping
Any tube, pipe or hose connected to the unit must be able to withstand the temperature generated and retain
the pressure. All pressurized components of the air system must have a pressure rating of 200 psi or higher.
Incorrect selection and installation of any tube, pipe or hose could result in bursting and injury. Connect piping
system to tank using the same size fitting as the discharge port.
8
Disconnect, tag and lock out power source then release all pressure
from the system before attempting to install, service, relocate or perform any
Do not lift or move unit without appropriately rated equipment. Be sure the unit is
securely attached to lifting device used. Do not lift unit by holding onto tubes or
Never use the wood shipping skids for mounting the
compressor.
Do not locate the compressor air inlet
near steam, paint spray, sandblast areas or
Failure to properly install the
tank can lead to cracks
Never use plastic (PVC) pipe for compressed air. Serious injury or death
could result.
Minimum Pipe Size For Compressed Air Line
CFM
25 feet
10
1/2 inch
20
3/4 inch
40
3/4 inch
60
3/4 inch
100
1 inch
Figure 3 - Location *
Figure 4 - Isolator pad
Length Of Piping System
50 feet
100 feet
1/2 inch
3/4 inch
3/4 inch
3/4 inch
1 inch
1 inch
1 inch
1 inch
1 inch
1 inch
250 feet
3/4 inch
1 inch
1 inch
1 inch
1-1/4 inch

Publicité

loading

Ce manuel est également adapté pour:

35wc7535wc7635wc7735wc7835wc7935wc80 ... Afficher tout