Operating Instructions
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Speedaire
Air Compressors
For Warranty & Service 1-888-606-5587
Do Not Return To Branch
Description
Air compressor units are intended to provide compressed air to power pneumatic
tools, operate spray guns and supply air for pneumatic valves and actuators. The
pumps supplied with these units have oil lubricated bearings. A small amount of oil
carryover is present in the compressed air stream. Applications requiring air free of
oil vapor should have the appropriate filter installed. The air compressor units are
to be mounted on a solid floor with isolation pads per the instructions provided.
Any other use of these units will void the warranty and the manufacturer will not
be responsible for problems or damages resulting from such misuse. Refer to the
enclosed "Replacement Parts Manual" to identify compressor as single stage or
two-stage.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
an imminently
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
Warning indicates
a potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Caution indicates a
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
Unpacking
After unpacking the unit, inspect care-
fully for any damage that may have
occurred during transit. Make sure to
tighten fittings, bolts, etc., before put-
ting unit into service.
Form 5S6013
Two-Stage
®
Do not operate
unit if damaged
during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.
General Safety Information
CALIFORNIA PROPOSITION 65
This product or
its power cord may
contain chemicals known to the State
of California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
GENERAL SAFETY INFORMATION
Since the air compressor and other
components (pump, spray guns, filters,
lubricators, hoses, etc.) used make up
a high pressure pumping system, the
following safety precautions must be
observed at all times:
1. Read all manuals included
with this product carefully.
Be thoroughly familiar
with the controls and the
proper use of the equipment.
2. Follow all local electrical and safety
codes as well as the United States
National Electrical Codes (NEC) and
Occupational Safety and Health Act
(OSHA).
Printed in U.S.A.
02433
Version 1
05/2013
4MU10A, 3VB60
Breathable Air Warning
This compressor/pump is NOT
equipped and should NOT be used
"as is" to supply breathing quality
air. For any application of air for
human consumption, you must fit the
air compressor/pump with suitable
in-line safety and alarm equipment.
This additional equipment is
necessary to properly filter and purify
the air to meet minimal specifications
for Grade D breathing as described
in Compressed Gas Association
Commodity Specification G 7.1 -
1966, OSHA 29 CFR 1910. 134, and/or
Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is
used for the purpose of breathing
air application and proper in-line
safety and alarm equipment is
not simultaneously used, existing
warranties are voided, and Dayton
Electric Mfg. Co. disclaims any
liability whatsoever for any loss,
personal injury or damage.
3. Only persons well acquainted with
these rules of safe operation should
be allowed to use the compressor.
4. Keep visitors away and NEVER allow
children in the work area.
MANUEL
5. Wear safety glasses and
use hearing protection
when operating the
pump or unit.
6. Do not stand on or use the unit as a
handhold.
7. Before each use, inspect compressed
air system and electrical components
for signs of damage, deterioration,
IN551601AV 5/13
E
N
G
L
I
S
H
E
S
P
A
Ñ
O
L
F
R
A
N
Ç
A
I
S

Publicité

loading

Sommaire des Matières pour Speedaire 4MU10A

  • Page 1 4MU10A, 3VB60 Operating Instructions Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
  • Page 2 4MU10A, 3VB60 Speedaire Operating Instructions Speedaire Two-Stage Air ® Compressors General Safety Information and pressure ratings to protect the 17. Use a face mask/respirator pressurized components from bursting. when spraying and spray (Continued) The flow rating can be found in the in a well ventilated area weakness or leakage.
  • Page 3 Speedaire Operating Instructions Models 4MU10A and 3VB60 Installation (Continued) INSTALLING A SHUT-OFF VALVE A shut-off valve should be installed NOTE: If compressor operates in a hot, Failure to properly install the on the discharge port of the tank to moist environment, supply compressor tank can lead to cracks at the control the air flow out of the tank.
  • Page 4 4MU10A, 3VB60 Speedaire Operating Instructions Speedaire Two-Stage Air ® Compressors minimum recommended wire sizes MOTOR HOOKUP AND STARTER Installation (Continued) for compressor installations. INSTALLATION MINIMUM PIPE SIZE FOR Branch circuit protection must be COMPRESSED AIR LINE MINIMUM WIRE SIZE provided as specified in the United USE 75°C COPPER WIRE...
  • Page 5 Speedaire Operating Instructions Models 4MU10A and 3VB60 Some residual oil may still be in the Circuit Breaker or Fused Disconnect pump leaving a thin coat on the sight Circuit Breaker or glass, however; there is not enough Fused Disconnect oil to operate the unit. Add oil only through the oil fill plug.
  • Page 6 4MU10A, 3VB60 Speedaire Operating Instructions Speedaire Two-Stage Air ® Compressors Operation (Continued) pressure settings on control components checked daily (See Figure 8). This valve above this limit. automatically releases air if the tank RECOMMENDED BREAK-IN PERIOD pressure exceeds the preset maximum.
  • Page 7 Speedaire Operating Instructions Models 4MU10A and 3VB60 AIR FILTER BELTS STORAGE Lock out and tag Never run the compressor pump If compressor is to be stored for a short the power then without an intake air filter nor with a...
  • Page 8 4MU10A, 3VB60 Speedaire Operating Instructions Speedaire Two-Stage Air ® Compressors Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Motor hums and runs 1. Low voltage or no voltage 1. Check with voltmeter, check overload relay in magnetic slowly or not at all starter or reset switch on motor.
  • Page 9 4MU10A, 3VB60 Manual de Instrucciones de Operación Por favor lea y guarde estas instrucciones. Léalas cuidadosamente antes de tratar de montar, instalar, operar o dar mantenimiento al producto aquí descrito. Protéjase usted mismo y a los demás observando toda la información de seguridad. ¡ El no cumplir con las instrucciones puede ocasionar daños, tanto personales como a la propiedad! Guarde estas instrucciones para referencia en el futuro.
  • Page 10 4MU10A, 3VB60 Manual de Instrucciones de Operación Speedaire Compresores de Aire de Dos Etapas Speedaire ® Informaciones Generales de presiones máximas de 13,79 bar para de ignición, incluyendo el compresor. compresores de dos etapas y de 10,34 Seguridad (Continuación) 16. No fume mientras esté rociando bar para compresores de una etapa, si están dañados, deteriorados,...
  • Page 11 Manual de Instrucciones de Operación Speedaire Modelos 4MU10A y 3VB60 Instalación (Continuación) debe instalar una manguera Flexible o Para conectar las tuberías al tanque, acoplador, entre el tanque y las tuberías utilice conexiones del mismo tamaño Nunca coloque la de servicio.
  • Page 12 4MU10A, 3VB60 Manual de Instrucciones de Operación Speedaire Compresores de Aire de Dos Etapas Speedaire ® PARA CONECTAR EL MOTOR E Instalación (Continuación) TAMAÑO MÍNIMO DEL ALAMBRE INSTALAR EL MOTOR DE ARRANQUE USE ALAMBRES DE COBRE DE 75°C TAMAÑO MÍNIMO DE LAS El circuito se debe proteger según...
  • Page 13 Manual de Instrucciones de Operación Speedaire Modelos 4MU10A y 3VB60 Quizás queden residuos de aceite en Cortacircuito o el cabezal lo cual dejaría rastros en la caja de fusibles Cortacircuito o ventanilla de vidrio; sin embargo, no caja de fusibles hay suficiente aceite para operar la unidad.
  • Page 14 4MU10A, 3VB60 Manual de Instrucciones de Operación Speedaire Compresores de Aire de Dos Etapas Speedaire ® Funcionamiento PRESOSTATO, ARRANQUE - PARO Mantenimiento (Continuación) NOTA: La presión máxima de trabajo de este compresor es 12,07 bar. Nunca PERIODO DE USO INICIAL exceda esta presión en ninguno de los...
  • Page 15 Manual de Instrucciones de Operación Speedaire Modelos 4MU10A y 3VB60 Mantenimiento guantes y tenga mucho cuidado cuando para permitir una deflección de 0,9 a vaya a limpiar o trabajar cerca de ellas. 1,2 cm al ejercer una presión normal (Continuación) con el dedo.
  • Page 16 4MU10A, 3VB60 Manual de Instrucciones de Operación Speedaire Compresores de Aire de Dos Etapas Speedaire ® Tabla de Identificación de Problemas Síntoma Causa(s) Posible(s) Medida Correctiva El motor hace ruido y 1. Voltaje bajo o nulo 1. Chequée con un voltimetro, chequée el relai de funciona lentamente o no sobrecarga del motor de arranque magnético o el...
  • Page 17 4MU10A, 3VB60 Manuel d’utilisation Veuillez lire et conserver ces instructions. Lire attentivement avant de commencer à assembler, installer, faire fonctionner ou entretenir l'appareil décrit. Protégez-vous et les autres en observant toutes les informations sur la sécurité. Négliger d'appliquer ces instructions peut résulter en des blessures corporelles et/ou en des dommages matériels ! Conserver ces instructions pour références ultérieures.
  • Page 18 4MU10A, 3VB60 Manuel d’utilisation Speedaire Speedaire Compresseurs d’Air à ® Deux Étages Généralités Sur La Sécurité et 1034 kPa pour les compresseurs à PRÉCAUTIONS DE PULVÉRISATION une étages DOIT être installée dans les (Suite) canalisations d’air ou dans le réservoir ou remplacer toutes pièces...
  • Page 19 Manuel d’utilisation Speedaire Modèles 4MU10A et 3VB60 Installation (Suite) Les tampons isolateurs 4C974 sont classification de pression de plus que recommandés. Ne pas trop serrer ou égal au réglage de la soupape de un endroit propre et bien ventilé. La les boulons en utilisant les tampons sûreté...
  • Page 20 4MU10A, 3VB60 Manuel d’utilisation Speedaire Speedaire Compresseurs d’Air à ® Deux Étages Installation (Suite) phase). “Wiring Design and Protection.” Article 210, dans l’article “For Motors and à l’équipement. Ne jamais utiliser un 3. La taille du fil de ligne est correcte Motor Controllers,”...
  • Page 21 Manuel d’utilisation Speedaire Modèles 4MU10A et 3VB60 mince sur le regard mais il n’y a pas Disjoncteur ou assez d’huile pour faire fonctionner le fusible sectionné Disjoncteur ou modèle. Ajouter de l’huile seulement fusible sectionné à travers du bouchon de remplissage d’huile.
  • Page 22 4MU10A, 3VB60 Manuel d’utilisation Speedaire Speedaire Compresseurs d’Air à ® Deux Étages Fonctionnement (Suite) dépassent cette limite. de marche. Inspecter la soupape de sûreté ASME quotidiennement (Voir Le compresseur se démarre et s’arrête permettre l’ajustage des segments de la Figure 8). Cette soupape dégage selon les réglages de manostat qui...
  • Page 23 Manuel d’utilisation Speedaire Modèles 4MU10A et 3VB60 FILTRE D’AIR COURROIES ENTREPOSAGE Mettre hors circuit Ne jamais utiliser le compresseur sans Pour l’entreposage à courte durée, et étiquetter la un filtre d’air d’admission ni avec un assuer que le compresseur soit source de puissance et dissiper toute filtre d’air d’admission obstrué.
  • Page 24 4MU10A, 3VB60 Manuel d’utilisation Speedaire Speedaire Compresseurs d’Air à ® Deux Étages Tableau de dépannage Symptôme Cause(s) possible(s) Action corrective Le moteur ronron et 1. Tension basse ou manque de tension 1. Vérifier avec un voltmètre, vérifier le relais de fonctionne lentement ou surcharge dans le démarreur magnétique ou rajuster...

Ce manuel est également adapté pour:

3vb60