Discharge Pipe and Pressure Tank Connections
PRE­CHARGE TANk
CONNECTION (FIGURE 4)
Step 1. Install two tees in the pump discharge port (see
Figure 4). The pipe size must be at least as large as
the discharge port.
Step 2. Run a pipe or reinforced hose from one arm of the
first tee to the port on the pre-charged tank.
Step 3. Connect the other end of the discharge tee to your
plumbing system.
Step 4. Check the pre-charge of air in the tank with an ordi-
nary tire gauge. The pre-charge should be 2 PSI less
than the cut-in setting of the pump's pressure switch.
The pre-charge is measured when there is no water
pressure in the tank. Your new pump has a 30/50 PSI
switch, so adjust the tank pre-charge pressure to 28
PSI.
Congratulations! You have just completed the tank
connection for your jet pump.
Please go to Pages 7 and 8 for electrical hookup.
To Household
Water System
Pressure
Switch
Figure 4: Pre-charged Tank Connections
Pump Priming
Tee and Plug
From
Well
1864 0795 FH
STANDARD TANk
CONNECTION (FIGURE 5)
Step 1. Install one tee in the pump discharge port
(see Figure 5).
Step 2. Run a pipe from the pump discharge port to the inlet
port of your tank. The pipe size must be at least as
large as the discharge port.
Step 3. Remove the 1/8" NPT pipe plug from the pump
Air Volume Control (AVC) port (see Figure 5). Run
tubing from the pump's AVC port (see Figure 5)
to the port on the AVC mounted on the tank. See
instructions provided with tank and AVC for details.
AVC port location will vary, depending on your
pump model (see exploded views, Page 9).
Congratulations! You have just completed the tank
connection for your jet pump.
Please go to Pages 7 and 8 for electrical hookup.
To Household
Water System
Pump
Priming Tee
and Plug
Pressure
Switch
Figure 5: Standard Tank Connections
Sealing Pipe Joints
Use only PTFE pipe thread sealant tape for making
all threaded connections to the pump itself. Do not
use pipe joint compounds on plastic pumps: they
can react with the plastic in pump components.
Make sure that all pipe joints in the suction pipe are
air tight as well as water tight. If the suction pipe
can suck air, the pump will not be able to pull water
from the well.
6
Air Volume
Control
Air Volume
Control Tube
From
Well
1865 0795FH