Installation (Well Pumps) - Pentair FH Serie Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation
REPLACING AN OLD PUMP
Hazardous voltage. Disconnect power to
pump before working on pump or motor.
Step 1. Drain and remove the old pump. Check the old pipe
for scale, lime, rust, etc., and replace it if necessary.
Step 2. Install the pump in the system. Make sure that all
pipe joints in the suction pipe are air-tight as well
as water tight. If the suction pipe can suck air, the
pump will not be able to pull water from the well.
Step 3. Adjust the pump mounting height so that the plumb-
ing connections do not put a strain on the pump
body. Support the pipe so that the pump body does
not take the weight of piping or fittings.
You have just completed the well plumbing for your
new shallow well jet pump. Please go to Page 6 for
discharge pipe and tank connections.
WELL POINT (DRIvEN POINT)
INSTALLATION (FIGURE 1)
Step 1. Drive the well, using "drive couplings" and a "drive
cap". "Drive fittings" are threaded all the way
through and allow the pipe ends to butt against each
other so that the driving force of the maul is carried
by the pipe and not by the threads. The ordinary
fittings found in hardware stores are not threaded all
the way through the fitting and can collapse under
impact. "Drive fittings" are also smoother than stan-
dard plumbing fittings, making ground penetration
easier.
Step 2. Mount the pump as close to the well as possible.
To Household
Water System
Not
to
Scale
Figure 1: Driven Point Installation
Pump Priming
Tee and Plug
Priming
Tee and
Plug
Check
Valve
Drive point
below water
level
Drive
Coupling
Drive
Point
1861 0795FH
Step 3. Use the fewest possible fittings (especially elbows)
when connecting the pipe from the well point to
the pump suction port. The suction pipe should be
at least as large as the suction port on the pump
(include a check valve if your pump is not equipped
with one – see Figure 1). Support the pipe so that
there are no dips or sags in the pipe, so it doesn't
strain the pump body, and so that it slopes slightly
upward from the well to the pump (high spots can
cause air pockets which can air lock the pump). Seal
the suction pipe joints with PTFE pipe thread sealant
tape. Joints must be air- and water-tight. If the suction
pipe can suck air, the pump cannot pull water from
the well. If one well point does not supply enough
water, consider connecting two or three well points
to one suction pipe.
You have just completed the suction piping for your
new shallow well jet pump. Please go to Page 6 for
discharge pipe and tank connections.
CASED WELL INSTALLATION, 2" OR
LARGER CASING (FIGURE 2)
Step 1. Mount the pump as close to the well as possible.
Step 2. Assemble the foot valve, strainer, and well pipe (see
Figure 2). Make sure that the foot valve works freely.
Step 3. Lower the pipe into the well until the strainer is five
feet above the bottom of the well. It should also be
at least 10 feet below the well's water level while the
pump is running in order to prevent the pump from
sucking air. Install a sanitary well seal.
To Household
Water System
Not
to
Scale
Figure 2: Cased Well Installation
Pump Priming
Tee and Plug
Suction Pipe
From Well
Priming
Tee and
Plug
Sanitary
Well Seal
Foot
10'
Min.
Valve
5–10'
1862 0795FH
4

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Fh 50Bfh50Fh50sFhp50Fh75

Table des Matières