Construction
[1] - cold water supply
[2] - domestic hot water outlet
[4] - hot water supply
[5] - hot water return
[6], [7] - solid fuel cooker connection
[15] - magnesium anode
[16] - cork 1½"
[17] - heating coil
[18] - external cylinder jacket
[19] - circulation fitting
[21] - pipe temperature sensor
A,B,C - dimensions specified in the technical data table
Storage capacity
80 l
100 l
120 l
140 l
Start up
Check out the pipe connections and make sure that you observe the connection
diagrams before start-up.
Cylinder, jacket and central heating system filling:
- turn on the valve on cold water supply pipe,
- turn on the hot water outlet valve (water outflow without the air bubbles indicates
that the tank is full),
- turn off the outlet valves,
- turn on the valves connecting the central heating system with cylinder,
- check for domestic water and heating water leaks,
- check for water leaks on 1½ cork and magnesium anode,
- check out the safety valve performance (see „Operation" section).
32
A
920
1125
1295
1365
Dimensions
B
483
688
858
928
C
-
1080
1250
1320