Manufacturer's recommendations:
• Read attentively the manufacturer's instructions.
• Positioning of the lamp and connecting of the power supply require great care. To make sure there is a good
conduction of current, the mechanical support and the electrical connections must be free form dirt and corrosion.
The clamps and brackets must be checked whenever the lighting unit has been transported.
• The lamp emits ultraviolet radiation. Direct exposure can be harmful to your health.
• It is recommended to avoid air draughts, also avoid exposing the lighting unit to bad weather.
• Use only when bulb in place
Technical characteristics:
Nominal absorbed voltage.......................................................................1200 Watts ............ 1200 Watts
Voltage use: .............................................. (European standard) 230/245 Volts 50Hz ..............................
Voltage use: ............................................(North American standard) 208 Volts 60Hz ....... 110Volts 60Hz
Minimum voltage of the power supply ....................................................... 198 Volts .............. 198 Volts
(Below this charge = possible ignition failure).
Voltage at the terminals of the lamp ........................................................... 100 Volts ............... 100 Volts
Amperage at the terminals of the lamp ....................................................13,8 Amps .............13,8 Amps
Luminosity of the lamp ........................................................................... 110 000 L's ........... 110 000 L's
Luminous effectiveness .............................................................................. 92 Lm/W ................92 Lm/W
Colour temperature ................................................................................ 5600 Kelvin ........... 5600 Kelvin
Base......................................................................................................... SFa 15,5-6 ............ SFa 15,5-6
Manufacturer's rated life ............................................................................750 hours ............. 750 hours
User's precautions:
• The lamplife, as given by the manufacturer, is a theoretic lamplife duration as "in laboratory conditions",
a cycle based on 3 hours on / 1 hour off. Briefer cycles reduce the duration of the lamplife.
• In operating conditions, it is uncommon for the lamp to still be fully efficient after 200 to 300 hours.
Its efficiency can decrease by 30%.
• Premature wearing of lamp under performing conditions is mainly due to frequent switching on. Better leave
the lamp on, through the performance, rather than switching it on repeatedly. ( The lamplife is reduced about
1 hour, each time the lamp is switched on ). It is advised to wait for 10 minutes before switching on again.
(This extends the duration of the lamp.)
• Use over 500 hours of the lamp : change the lamp even if it still lights up.
New lamp:
• To achieve a good ionization of a new lamp, when using it for the first time, it is recommended to leave it on
for a few hours.
• Preserve carefully the guarantee slip of the lamp, as it may be asked for in the event of a dispute.
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle - phone: 33 (0)3.44.26.51.89 - fax: 33 (0)3.44.26.90.79 - www.robertjuliat.fr
TECHNICAL FILE
1200W HMI FOLLOW SPOTS

ADMISSIBLE LAMPS :-

OSRAM: HMI 1200W/GS
PHILIPS: MSI 1200
HMI 1200
Thank you.
1149 & 1449 /
B, C & CB
Section A - 9
-
1149 & 1149B
1149C & 1149CB

Publicité

Table des Matières
loading

Table des Matières