Disconnect from the mains before any servicing.
Service only by qualified technician.
MAINTENANCE
ASPHERIC LENS & REFLECTOR.
- Disconnect from the mains.
- Unscrew the four screws 1 and unplug the Earth
link 2 then remove the lamp house bonnet 3 .
- Unlock 4 and remove the aspheric holder 5
and the reflector holder 6 .
- Clean the lenses 7 and the reflector 8 with a soft
dry cloth.
- Remount all in reverse order.
- Clean in the same way, the lenses
in the lens tube.
SPARK-GAP.
- Disconnect from the mains.
- Open the lamp house bonnet.
- Unscrew the nut a , while holding in place the
counter-nut b .
- Then, unscrew the counter-nut b .
- Adjust, with a 2,5 hexagon key, the upper electrode c to
1 mm from the electrode.
- Tighten the counter-nut b and the nut a .
• Gap adjustment is factory set.
Interfere only in case of a faulty starting.
CHANGING THE COLOUR FRAMES AND COLOURS.
- Remove the colour frame from the slot 1 .
- For changing a colour, open the 4 clips 2 .
- Cut out a colour 3 : Ø 207.