Technical Data
Power supply:
Performance: max.
Fuse:
Safety check:
Capacity of water reservoir:
Air performance max. (free blowing)
Vapor performance max.
Length of power cord:
Weight (w/out water):
Measurement (W x H x D):
Maximum inlet water pressure:
Minimum inlet water pressure:
Error Correction
Error
Cause
Not functioning at all
Unit not connected to power supply
(no STANDBY indicator)
Fine-fuse of the circuit board blown
No Function (STANDBY -
Reed switch deactivated unit
Symbol blinks)
Water level indicator
Water level too low
missing
Copper electrodes dirty
Softenend water has been used
Unit runs, but evapora-
Tension too low
tion filter does not move
Unit leaks water
Evaporation filter rubs against casing
Check water reservoir for damages
Automatic water supply
Water inlet valve (solenoid valve) does not
runs uninterrupted
close
Water guard gives
Water leaks
acoustic signal
230V AC
max. 58 W
2 A
CE
approx. 25l
600 m3/h
1,4 l/h
2,5 m
21 kg
74 x 71 x 41 cm
1 MPa
0 MPa
Solution
Check power input
Replace fine-fuse of the circuit board
Check casing that it is completely locked
refill water
Clean copper electrodes
Use ordinary tab water
Increase tension, see „Changing of Filters" (page 14)
If still too low, replace evaporation filter.
Possibly exchange driving roller.
Increase tension see „Changing of Filters" (page 14)
Replace water reservoir
Dirt residue in the water feed tube
Check Electrodes for pollutants
Replace solenoid valve
check water quality
Check for the cause. Cut off supply for water guard from the net
for some seconds
16