Setup/ Location
Open the packaging and remove all packaging parts from the humidifier.
Setup the unit onto an even, horizontal surface.
For an optimal function, the unit may be set up near a heat resource. However, the temperature in
that area should not exceed 70° C. Check the unit for any possible transportation damages.
Check whether the delivery is complete, and that all parts belonging to the unit are fitted properly.
Operating your unit
Before operating your unit, you should ensure that all parts are installed appropriately and that the water reservoir is filled.
Please proceed as follows:
Power Supply
Check whether local mains voltage is the same as the one on the identification label. The identification label is located above the
power/net inlet cable and below the fan motor. To locate the label, you first have to remove the outer case of the unit.
Operating the humidifier B 300
The control panel of the B 300 informs you about the current status of the unit. You can
read the room humidity, the set fan speed and the water level. You can make settings on
the unit with the „+/-" and AIR-switches.
The indicator display and setting of the relative humidity takes place in 5% increments.
Therefore, the values may deviate when using other control devices. At 3% and 8%, the
display jumps over to the next higher value (e.g. actual humidity = 43% corresponds to =
45%) The user can, to a minor degree (+/- 5%), calibrate the display accuracy. Read more
about this in the paragraph „Adjusting the humidity indicator" (page 15).
Switching On/Off and setting of the fan level – AIR-switch
The B 300 is switched on or off by pressing the AIR-switch twice. By repeatedly depressing the switch, the different fan modes can be changed.
STANDBY:
The humidifier is switched off and without function. Attention: The unit still receives power.
ƒ
LOW:
The fan runs on the lowest output level. The noise level is optimized
ƒ
HIGH:
ƒ
The fan runs on the highest output level, for a maximum output of humidity and air purification.
AUTO:
The fan runs automatically according to the performance requirements, which is controlled by the actual room humidity.
ƒ
If the AIR-switch is pressed, the symbol on the indicator display starts to blink and, after pressing the switch again, jumps to the next operating
mode. By depressing the AIR-switch again, the status can be changed to the next mode. In this condition, the symbol blinks until the desired
status is reached and for 2 seconds, another setting was not selected. After that, the symbol no longer blinks, and the selected operation
mode is performed. Please note that when the AIR-switch is depressed the first time, only the setting mode is started and the operating mode
does not change. Only by depressing the AIR-switch again, the operating modus is changed.
Changing of the – HUMIDITY-switch
If the unit is turned on, with the HUMIDITY-switches "+" or "-" the desired relative humidity can be changed upward or downward. During the
pressing of the switches "+" or "-" the indicator jumps from the actual room humidity to the desired value according to the setting. By repea-
tedly pressing the "+" or "-" switch, the value is accordingly changed. If the desired value is adjusted, the indicator display jumps back after a
few seconds to the actual room humidity and the new desired value was recorded and stored.
Function „Switch/ key lock"
To lock the control keys for children or strangers, to disable the use of the operating panel a key lock is integrated. It is switched on and/or
deactivated by simultaneous pressing of the 3 keys (AIR-switch and the two HUMIDITY-switches) for 3 seconds. If the key disabling device is
activated and a key is pressed, all control elements in the display blink. The key lock must be deactivated. Only after pressing the 3 keys again,
the settings can be changed.
Safety of the unit
The unit is equipped with two reed contact, which, when opening the casing of the unit, switches via the control all components of the B 300
off. The disconnection via the reed contact is signalled via a flashing standby indicator. Only if the casing is completely closed, the standby
indicator turns off and the air humidifier takes up again operations.