1. Switch off the product.
A
2. Remove the fan unit with wind guard
and front panel.
A
B
3. Remove the front panel.
2
4. Remove the wind guard.
5. Use a dry cloth to clean the fan unit,
the wind guard and the front panel.
6. Mount the fan unit with wind guard and
front panel back onto the wall-mount-
ing frame from which you previously
removed it.
0020236695_00 recoVAIR Operating instructions
C
B
1
Care and maintenance 6
6.2 Cleaning the filter and
regenerator
Conditions: LED on the product lights up red
OR: Filter defective or beginning to tear
▶
Switch off the product.
▶
Remove the fan unit with wind guard
and front panel.
▶
Remove the regenerator (on which the
filters are mounted) from the pipe.
▶
Pull the filters off of the regenerator.
▶
Using its lowest power setting, use a
vacuum cleaner to carefully vacuum
the filters.
▶
Use water to rinse out the filters.
▶
Using its lowest power setting, use a
vacuum cleaner to carefully vacuum
the regenerator.
▶
Use water to rinse out the regenerator.
Conditions: Drying the filter and regenerator
▶
Secure the filters back onto the regen-
erator.
▶
Ensure that the tension cable is posi-
tioned securely and is not damaged.
▶
Plug the regenerator back into the
pipe until it approximately reaches the
centre of the wall.
– The regenerator and tension cable
must not touch the fan's impeller.
▶
Mount the fan unit with wind guard and
front panel back onto the wall-mount-
ing frame from which you previously
removed it.
▶
Reset the LED.
– See the operating instructions for the
control or for the remote control.
67