Adjusting the automatic safety release function
The automatic release is designed to protect the trans-
mission components from overloads (e.g. if the dispens-
er jams, etc.).
The device is already set by the manufacturer during the
testing stage, but can be adjusted by the user according
to requirements.
For adjustments, proceed as outlined below.
1) Turn the ring nut (A) clockwise to increase the release
resistance (i.e. less sensitive).
Turn the ring nut (A) anticlockwise to decrease the
release resistance (i.e. more sensitive).
Adjusting the float skid
UN41 0469BM
Proceed as outlined below.
1) Loosen the screw (A).
2) Raise or lower the float skid.
English language
ADJUSTMENT INFORMATION
UN41 0117LF
A
3) Tighten the screw (A).
4) Adjust the load applied to the ground (see "Adjusting
the planting force" - page 16).
18
5
Use and maintenance