2.5 Technical data

(the data on the unit rating plate are applicable)
Typ
Heat output
V
Partial power
Stage ! kW
Rated power
Stage !! kW 13.2
Min. flow rate to activate unit
Stage
! l/min
Stage !! l/min
Flow rate limiter
l/min
Pressure loss *
MPa (bar)
Flow rate
l/min
Nominal water volume
Type of construction
Rated overpressure MPa (bar)
Weight
kg
Protection class to
DIN EN 60335
Protection mode to
DIN EN 60529
Test mark
Water connection
Electrical connection
Max. system-impedance
Z max
$
to DIN EN 61000-3-11
Heating element
Cold water inlet
Use in waters
Total alkaline earths
Overall hardness (earlier unit)
Hardness range (earlier unit)
Table 3
* Pressure drop values also apply to the minimum flow pressure in accordance with DIN 44851 / Flow rate for heating from 10 °C to 55 °C
(% # 45 K). A pressure drop of 0.1 MPa (1 bar) is recommended for pipe network dimensioning, in line with DIN 1988 Part 3, Table 4.

2.6 Installation location

The DHF ... C compact control is to
be installed vertically in accordance
with
A
(over-sink or under-sink) in a
closed, frost-free room, as near as possible
to the tap point (a dismantled unit is to be
stored in frost-free conditions, since resi-
dual water always remains in the unit).
14
DHF 13 C
DHF 15 C
compact
compact
control
control
400
400
6.6
7.5
15
3.0
3.0
4.5
4.5
6.5
6.5
0.055 (0.55)
0.055 (0.55)
4.5
4.5
l
2.7 Preparing for unit instal-
lation
B
Turn locking cap (3) to the left and with-
draw.
Unscrew cover securing screw and re-
move device cover.
– Detach mounting bracket (19) from the
unit.
– Thoroughly flush through the cold water
supply pipe.
– In the case of a replacement installation,
the available cold water 3-way three-way
isolating valve (
used.
– With the help of the template (separate
this from the operating and installation
instructions), determine the position of
the cable entry (concealed connection)
and the mounting bracket (19).
DHF 18 C
DHF 21 C
compact
compact
control
control
400
400
9
10.5
18
21
3.9
4.4
5.9
6.4
7.0
7.5
0.06 (0.6)
0.06 (0.6)
5.9
6.4
0,6
Closed
1 (10)
4.0
1
IP 24
See unit rating plate
G ½ (external thread)
3/PE ~ 400 V
Copper tubular heating element
& 20 °C
& 2.5 mol/m³
& 14 °d
Inclusive of 2 (medium hard)
D
, 6) can if necessary be
DHF 24 C
DHF 12 C1
compact
compact
control
control
400
220
230
12
8
8.8
24
12
13.2
4.9
3.0
7.6
4.5
8.0
6.5
0.07 (0.7)
0.055 (0.55)
7.6
4.5
1/N/PE ~
220/230 V
0.14
G
Cut the electrical connection cable to
length and strip.
C
Secure the mounting bracket.
When replacing DHF/DHA old models
(height 370 mm), the available drilled
securing holes (20) can be used.
– Secure the unit to mounting bracket with
the screwed sleeve (14). Using the nut
on the threaded bolt (21), unevennesses
in the wall, caused for example by mis-
aligned tiles, can be compensated for
(maximum 12 mm).
DHF 13 C3
compact
control
230
6.6
13.2
3.0
4.5
6.5
0.055 (0.55)
4.5
3/PE ~ 230 V