Troubleshooting
PROBLEM
Too much/not enough material
dispensed
Rate gate linkage will not open fully Dial is in wrong position
Motor is not turning on
Material is not falling through
hopper gate
Agitator is missing or worn
CAUSE/CONDITION
Rate gate not opened to correct
position
Battery harness not connected to
battery
Motor harness not connected to
motor
Fuse is blown
On/Off switch light is fl ashing on
and off every 2 seconds
On/Off switch light is fl ashing on
and off every 1 second
Material is too dense, compact, or
moist.
Material is too moist
Material is clumpy
Gate is not opened far enough for
material type
High amount of usage
23
REMEDY
Check dial settings and rate gate
linkage position
Turn dial so milled out portion
(#9.9) allows gate to open fully
Ensure battery harness is properly
connected to battery and motor
controller.
Ensure motor harness is connected
to motor and motor controller.
Check and replace 15 amp fuse.
To avoid electrical damage, only use
15 amp.
Under voltage condition. Turn
switch off, wait 5 seconds and turn
switch on.
Overload condition, Turns switch
off, wait 5 seconds and turn switch
on. If problem continues, turn
switch off.
Turn off switch, remove agitator.
Scoop material from hopper and
replace with dry material
Ensure screen is in place.
Open gate in small increments.
Replace agitator with part number
1008241. Do not use any other
agitator.
1008754 Rev. A