6.4 Diagnostics

Diagnostics
The motor does
The remote control range
not respond
is reduced
to commands
from the remote
control
Non-memorised remote
control
Motor unlocked
The indicator
The electronics unit is on
light
on the
standby
electronics unit
No power supply to the
is off
control electronics
The indicator light
of the electronics unit is flashing:
1 flash
Operation using the
backup battery
2 flashes
Motor waiting for gate
travel to be programmed
3 flashes
Faulty photoelectric cells
4 flashes
Short circuit of electronic
unit "START" output
(terminals 5-6)
5 flashes
Motor thermal protection
device activated
6 flashes
Short circuit of electronics
unit's "BUS" output
(terminals 3-4)
Short circuit of electronics
unit's "24 V output"
(terminals 7-9)
Short circuit of electronics
unit's "orange light"
output (terminals 8-9)
Motor short circuit
7 flashes
Electrical fault
Repairs
• Check the remote control battery
("Replacing the remote control battery", see
page 17).
• Check the aerial of the electronics unit (wiring,
position, see page 3).
• Check that there are no outside elements that
may be interfering with the radio signal (electric
pylon, metal reinforced walls, etc.). If this is the
case, fit an offset aerial.
Memorise the remote control (see page 16).
Lock the motor.
Press
for 2 seconds to reactivate the
electronics unit.
• Check the mains power supply.
• Check the power supply cable.
Check the mains power supply.
Start auto-programming procedure (see page 7).
• Check that there is nothing obstructing the cells.
• Check cell alignment.
• Check the cell wiring (see page 9).
• If the cells are deliberately disconnected, perform
the procedure "Deactivating automatic closing -
returning to standard operation" page 13.
Check the accessories connected to the electronic
unit's "START" output.
Allow the motor to cool down for several minutes.
Check the accessories connected to the electronic
unit's "BUS" output.
Check the accessory connected to the electronic
unit's "24 V" output.
Check the wiring of the orange light (see page 9).
Check the motor wiring (see page 4).
Contact Somfy assistance.
EN - Replacing the FREEVIA electronics unit - SOMFY
19

Publicité