Technical Data
Precision / Measuring range
Operating conditions
Storage conditions
Radio module
operating data
Power supply
Operating time
Dimensions (W x H x D)
Sensor
Weight (incl. battery)
Subject to technical changes without notice. 18W51
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be collected
separately for disposal according to the European
Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=AGQ
ThermoControl Duo
± 1°C (0°C ... 100°C)
± 2°C (-20°C ... 0°C / 100°C ... 150°C)
± 3°C (-50°C ... -20°C / 150°C ... 200°C)
± 5°C (200°C ... 300°C)
0°C ... 50°C, max. humidity 80% rH,
no condensation, max. working altitude
2000 m above sea level
-10°C ... 70°C,
max. humidity 80% rH
Bluetooth LE 4.x interface; Frequency band:
ISM band 2400–2483.5 MHz,
40 channels; Transmission power:
max. 10 mW; Bandwidth: 2 MHz;
Bit rate: 1 Mbit/s; Modulation: GFSK/FHSS
1 x 3V CR2032
150 h
80 x 135 x 40 mm
90 mm, ø 2,5 / 4 mm
145 g