Safety Considerations

Read all instructions before attempting to operate
this machine and save these instructions.
Warning! When using electric machines, basic safety
precuations should always be
the risk of fi re, electric shock and personal injury,
including the following:
1. Work area environment
Don´t expose the machine for rain. Don´t use
it in damp or wet locations or in presence of
fl ammable liquids or gases.
2. Overload
Never let the machine operate fully throttled.
Always follow the regulations pertinent to the
material you are working with ie asbestos.
Don´t use the machine for purposes that it isn´t
intended for.
3. Body injuries
Never let the suction come in contact with
parts of the body. The strong suction effect can
hurt the blood-vessels in the skin. Do not re-
pair the electric components yourself, get
somebody qualifi ed. Faults may cause injury.
See also below under warnings.
4. Don´t abuse cord

TECHNICAL DATA

HxWxL
Weight
Inlet
Collecting sack 50 l
Hose length (φ 50)
Flow, max
Neg. pressure, max
Power consumption
Fine fi lter polyester, area
Degree of separation
(DIN 24184/3)
Filter area, microfi lter
Degree of separation,
microfi lter (DOP)
Sound level */
Sound eff ect level
followed to reduce
50 Hz
60 Hz
1800x760x1150 mm
ca 200 kg
ca 220 kg
φ 76 mm
φ 76 mm
kPa
700 x 850 mm
40
5-50 m
5-50 m
3
3
500 m
/h
560 m
/h
40 kPa
45 kPa
9.2 kW
11 kW
20
4.8 m
2
4.8 m
2
99.9 %
99.9 %
2
2
2.5 m
2.5 m
> 99,97 % > 99,97 %
< 75 dB(A) < 75 dB(A)
93 db
93 db
DC 5800c 9,2/11 kW S - 8
Never pull the machine by cord. Keep cord
from heat and sharp edges. Check the electric
cable regularly if damage.
5. Important measure
With cleaning and maintenance on the mach-
ine, the power cable should be dis-connected
from the supply.
6. Maintain the machine with care
Keep machine clean and check that the hose
is entired and that all gaskets are tight. Follow
instructions. Keep handles dry and free from
oil and grease.
7. Checking of damage
Before futher use of the machine it should be
carefully checked that the machine is unda-
maged. If there are any damaged parts these
should be repaired by of a Dustcontrol authori-
zed service center.
8. Warning
Use only accessories and replacable parts
which are available in Dustcontrol catalogue.
When using faulty parts or pirate parts (espe-
cially fi lter) the machine could leak out
unhealthy dust which can cause personal
injuries.
Vacuum producer capacity
11 kW S 60 Hz
9.2 kW S
200
400
*/ Sound level at 1.6 m height and 1 m distance
according to DIN 45635 Section 1 (4/84) in free
space and at maximum airfl ow.
600
800
1000
Part No 9091