Description
The DC 5800c 9.2/11 kW S is driven by a two stage
connected turbopump with extremely high vacuum
effekt. The machine is intended for use on material
transportation systems or for cleaning of abnormally
heavy material. With theese types of systems it is
recommended to use a preseparator.
The high vacuum effect can also be used in conven-
tional systems where extra long hose or pipe systems
are required. Filter cleaning is done with reverse pulse
which gives excellent fi lter economy.
Operation
Connect the machine to a suitable power source ac-
cording to the specifi cation plate on the machine. If
the electrical cord on the machine becomes damaged
it should be replaced.
The fi lter should be cleaned 1-2 times per day with
continuous running or if the machine is equipped with
a fi lter monitor, when this is in the red area.
For fi lter cleaning:
1. Start the machine.
2. Close the shutter valve on the machines inlet.
3. With slow, even motion open the pulse top by
lifting the handle. Repeat three to six times.
4. Open the shutter valve.
5. If the fi lter condition meter reads green work
The extraction system functions with negative pres-
sure (vacuum) that draws the air through suction
casings/nozzles, hose system, separator and fi lter
system. Coarse separation of dust occurs in the units
cyclone which is a highly effi cient separator for larger
particulate. The fi ne dust is separated and contained
by the units fi lter system. Separated material is col-
lected for disposal in the plastic sack or container at
the base of the cyclone.
can continue, if in the red, pulse clean again. If
after several repetitions, the fi lter condition still
shows red the fi ne fi lter must be changed.
The plastic sack should be changed only after the
fi lter has been cleaned. The sack should be changed
when the dust level is about 5 cm under the foot valve.
The plastic sack should be sealed after removal from
the machine.
Use only original plastic sacks.
DC 5800c 9,2/11 kW S - 9
Part No 9091