PRODUCT DIMENSIONS AND CLEARANCES
30" Wide Range Models
29-7/8" Width
29 3/8" Depth to
Front of Bullnose
35-1/4" to 36-3/4"
Height to trim. Trim
to be flush or higher
than countertop.
28-1/2" Depth to
Front of Door
WARNING
Installations without a
hood require 48" minimum to combustibles.
A custom hood installation with exposed
horizontal combustible surfaces must have
an Auto-On feature. Refer to hood installation
instructions for specific hood clearances.
The surface of the entire back wall above
the range and below the hood must be
covered with a non-combustible material
such as metal, ceramic tile, brick, marble or
other stone.
CAUTION
To prevent drafts from
affecting burner operation, seal all openings
in floor under appliance and behind
appliance wall.
** A s defined in the National Fuel Gas Code (ANSI
Z223.1/CSA B149.1, Current Edition). Clearances
from non-combustible materials are not part of the
ANSI Z21.1/CSA 1.1 scope and are not certified by
CSA. Clearances less than 12" must be approved by
local codes and/or the authority having jurisdiction.
ADDITIONAL CLEARANCES:
Allow 12" minimum clearance to an adjacent wall on
each side.
Working areas adjacent to the rangetop should have
18" minimum clearance between countertop and the
bottom of the wall cabinet.
For island installation, maintain 2-1/2 in. minimum from
cutout to back edge of countertop and 3 in. minimum
from cutout to side edges of countertop (see top view).
31-2000667 Rev. 1
Design Information
1"
Countertop
to Cooking
Surface
3-1/4"
to 4-3/4"
Toekick/
leg Height
16"
Max.
Universal Utility Locations
4-5/8"
11-3/8"
Gas/
6-1/2"
Electric
Electric
2"
30"
30"
Minimum
48" Minimum
to Combustibles
Non-
Combustible
Material **
Minimum
Each
Side
30" Min.
Back
2-1/2" Min.
3" Min.
Island
Cutout
Top View
7-3/8"
2"
12" Minimum
to Adjacent Wall
18"
Min.
12"
3" Min.
7