ELECTRICAL CONNECTIONS

WARNING
This appliance must be properly
grounded.
WARNING
All new constructions, mobile
homes, recreational vehicles and installations where
local codes do not allow grounding through neutral,
require a 4-conductor UL-listed range cord.
WARNING
To prevent fire or shock, do not use
an extension cord with this appliance.
WARNING
To prevent shock, remove house
fuse or open circuit breaker before beginning
installation.
We recommend you have the electrical wiring and
hookup of your range connected by a qualified
electrician. After installation, have the electrician show
you how to disconnect power from the range.
You must use a single-phase, 120/208 VAC or
120/240 VAC, 60 hertz electrical system. If you
connect to aluminum wiring, properly installed
connectors approved for use with aluminum wiring
must be used.
Effective January 1, 1996, the National Electrical
Code requires that new construction (not existing)
utilize a 4-conductor connection to an electric range.
When installing an electric range in new construction,
mobile home, recreational vehicle, or an area where
local codes prohibit grounding through the neutral
conductor, refer to the section on four-conductor
branch circuit connections.
Check with your local utilities for electrical codes which
apply in your area. Failure to wire your oven according
to governing codes could result in a hazardous
condition. If there are no local codes, your oven must
be wired and fused to meet the National Electrical
Code, NFPA No. 70 – latest edition, available from the
National Fire Protection Association.
This appliance must be supplied with the proper
voltage and frequency, and connected to an individual,
properly grounded, (50 amp for 48" ranges, 30 amp
for 36" and 30" ranges) branch circuit protected by a
circuit breaker or time-delay fuse.
Use only a 3-conductor or a 4-conductor UL-listed
range cord. These cords may be provided with ring
terminals on wire and a strain relief device.
14
Installation
6
ELECTRICAL CONNECTIONS (Cont.)
A range cord rated at 40 amps with 125/250 minimum
volt range is required. A 50 amp range cord is not
recommended but if used, it should be marked for
use with nominal 1
Care should be taken to center the cable and strain
relief within the knockout hole to keep the edge from
damaging the cable.
NOTE: Use of automatic, wireless or wired external
switches that shut off power to the appliances, are not
recommended for this product.
The access
plate is on
the back of
the range.
7
4-WIRE POWER CORD
INSTALLATION
NOTE: A 4-wire cord is connected to the range at the
factory. Use the following steps to change an existing
installation from a 3-wire cord back to a 4-wire cord.
WARNING
must be connected to the neutral terminal located
in the lower center of the terminal block. The power
leads must be connected to the lower left and the
lower right terminals of the terminal block. The 4th
grounding lead must be connected to the frame of the
range with the ground plate and the ground screw.
■ R emove the 3 lower terminal screws from the
terminal block. Remove the ground screw and
ground plate and retain them.
■ R emove the ground strap.
DO NOT DISCARD THE GROUND STRAP OR
ANY SCREWS.
■ I nsert the one ground screw into the power cord
ground wire terminal ring, through the ground plate
and into the frame of the range.
" diameter connection openings.
3
8
The neutral wire of the supply circuit
31-2000667 Rev. 1