Construction for level
Electrical connection
Han 8D is identical to Han 8U.
1)
7.4
Display, keyboard and auxiliary power
Display and user interface
Keys
Display
Auxiliary power U
H
Terminal voltage at transmitter
Ripple
Noise
Auxiliary power
Separate supply voltage
Bus voltage
● Not
● For intrinsically safe operation
Current consumption
● Max. basic current
● Starting current ≤ basic current
● Max. current in event of fault
Error shut-down electronics (FDE)
present
7.5
Certificates and approvals
Certificates and approvals
Classification according to Pressure
Equipment Directive (PED 97/23/EC)
Drinking water
Explosion protection
● Intrinsic safety "i"
Marking
46
Screw terminals
Cable inlet using the following screwed joints:
● Pg 13.5
● M20 x 1.5
● ½-14 NPT or Han 7D/Han 8D connector
● M12 connector
3 for on-site programming directly at the device
● With or without integrated display (optional)
● Cover with inspection window (optional)
HART
● DC 10.5 V ... 45 V
● In the case of intrinsically safe
operation 10.5 V ... 30 V DC
U
≤ 0.2 V (47 ... 125 Hz)
SS
U
≤ 1.2 mV (0.5 ... 10 kHz)
eff
HART
● for gases of Fluid Group 1 and liquids of Fluid Group 1; meets requirements of
Article 3 Para. 3 (good engineering practice)
● only for flow rate:
for gases of Fluid Group 1 and liquids of Fluid Group 1; fulfills the basic safety
requirements as per article 3, Para 1 (appendix 1); classified as category III,
module H conformity evaluation by TÜV Nord
In preparation
PTB 11 ATEX 2011 X
II 1/2G Ex ia/ib IIC T4/T5/T6 Ga/Gb
1)
PROFIBUS PA or Foundation Fieldbus
Bus-powered
Not necessary
9 ... 32 V
9 ... 24 V
12.5 mA
Yes
15.5 mA
Yes
PROFIBUS PA or Foundation Fieldbus
SITRANS P, DS III series (7MF4.33.. 7MF4.34.. 7MF4.35..)
A5E03434626-02, 12/2012

Publicité

loading