Electrical Connection RapidHeat
Install a separate 120 VAC 15 AMP dedicated circuit with GFCI
protection. With a #8 solid copper wire, bond the heater to the house
electrical panel or approved local bond. A bonding lug is provided on
the heater.
At initial start-up and before each use thereafter with power ON,
push the GFCI test button. The reset button should pop out. Push
this button in to reset. If the interrupter fails to operate in this manner,
there is a ground current flowing or a device malfunction, indicating
the possibility of electrical shock. Turn off power and do not use
the bath until the source of the problem has been identified and
corrected.
ELECTRICAL CONNECTION RAPIDHEAT
T M
HEATER
Electrical Connections (Canada only)
The electrical installation is subject to inspection and approval by the
local inspection authority. Employ a licensed electrician to connect the
equipment to the supply in accordance with the local electrical code.
Check that the power supply available corresponds to that required by
the motor.
The whirlpool bath must be connected to a separate 120VAC, 15AMP,
single-phase circuit or a separate 120VAC, 20AMP, single-phase
circuit (refer to the table for your model). The RapidHeat heater must
be connected to a separate 120VAC, 15AMP, single-phase circuit.
Use No. 14 AWG wire, or heavier, to run a separate fused circuit from
the distribution panel. Note that protection of the circuit by a ground
fault circuit interrupter is mandatory under the Canadian Electrical
Code, Part 1, Section 68. Ground fault circuit interrupters are available
from your local electrical supplier.
DANGER: RISK OF ELECTRIC SHOCK. Connect only to a cir-
cuit protected by a Ground Fault Circuit Interrupter.
CAUTION: Operating the motor/pump without enough water in
the bath can cause leaking and permanent damage to the pump.
Before power is applied to the installation, make sure the switch
is in the OFF position to avoid pump damage.
SEPERATE GFCI
PROTECTED CIRCUITS
WIRING DIAGRAM BATH
120V SINGLE PHASE POWER SUPPLY
PROTECTED BY A GROUND FAULT CIRCUIT
INTERRUPTOR
NEUTRAL
N
L1 LIVE
N
L1
DO NOT OPERATE THE WHIRLPOOL BATH UNLESS
IT IS CONNECTED TO A CLASS A GFCI (GROUND
FAULT CIRCUIT INTERRUPTOR). TEST THE GFCI AT
LEAST ONCE A MONTH.
WIRING DIAGRAM RAPIDHEAT
120V SINGLE PHASE POWER SUPPLY
PROTECTED BY A GROUND FAULT CIRCUIT
INTERRUPTOR
NEUTRAL
N
L1 LIVE
DO NOT OPERATE THE WHIRLPOOL BATH UNLESS
THE HEATER IS CONNECTED TO A CLASS A GFCI
(GROUND FAULT CIRCUIT INTERRUPTOR). TEST
THE GFCI AT LEAST ONCE A MONTH.
12
(CANADA ONLY)
FUSED DISCONNECT SWITCH
OR CIRCUIT BREAKER
OPTIONAL:
30 MINUTE TIMER
(SINGLE POLE SWITCH)
WALL MOUNTED
ON/OFF SWITCH
FIELD WIRING
JUNCTION BOX
LIGHT
TRANSFORMER
MOTOR
(CANADA ONLY)
FUSED DISCONNECT SWITCH
OR CIRCUIT BREAKER
OPTIONAL:
30 MINUTE TIMER
(SINGLE POLE SWITCH)
WALL MOUNTED
ON/OFF SWITCH
FIELD WIRING
JUNCTION BOX
HEATER