Selecting The Boiler Location; Positioning The Boiler - Baxi LUNA HT 380 Notice D'installation Et D'entretien

Masquer les pouces Voir aussi pour LUNA HT 380:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CLEARANCES REQUIRED
FOR CLOSET INSTALLATION
1.77 in /
45.0 mm
1.57 in /
40.0 mm
0 in / 0 mm between the Back of the Unit and the wall
Note: It is recommended that service clearances are considered when locating a suitable area for the unit.
Fig. 4
WARNING
• The boiler must not be installed on carpeting.
• Keep boiler area clear and free from flammable vapors and liquid.
1.
Check for nearby connections to:
System water piping;
Venting connections;
Gas supply piping;
Electrical power.
2.
Check the area around the boiler. Remove any combustible materials, gasoline and other flammable liquids.
3.
Ensure the Boiler's gas control system components are protected from dripping or spraying water.
WARNING
Failure to keep boiler area clear and free of combustible materials, gasoline and other flammable liquids and
vapors can result in severe personal injury, death or substantial property damage.
0 in / 0 mm between the Back of the Unit and the wall
1 Decide the position of the boiler taking into account the clearances required for servicing and the flue terminal position.
WARNING
Remove any combustible materials, gasoline and other flammable liquids away from the hot water pipes.
2 Tape the template to the wall (ensure it is level and upright) and mark the position of the holes for the boiler mount- ing
bracket and plumbing connections. If rear exit flue is to be used, mark the position of the hole for the flue.
3 If side exit flue is to be used, continue to mark the horizontal centre line of the flue across the wall to the side wall, then
along the side wall (ensure the lines are level). This will give the position of the centre of the hole for the flue.
4 Cut the 4.33 in / 110.0 mm diameter hole in the wall for the concentric flue.
INSTALLATION AND SERVICING INSTRUCTIONS
1.77 in / 45.0 mm
1.77 in /
45.0 mm

3.1 SELECTING THE BOILER LOCATION

3.2 POSITIONING THE BOILER

12
CLEARANCES
FOR COMBUSTIBLES
17.72 in /
450.0 mm
1.77 in / 45.0 mm
7109741.01 - en