3.3 TEMPERATURE CONTROL

Press
and
When the burner is lit, display shows the symbol
HEATING: while boiler is operating in heating mode, display shows the flashing symbol
When connected to an Outdoor Temperature Sensor,
DHW: While boiler is operating in DHW mode, display shows the flashing symbol
3.4 BOILER INFORMATION MENU (SEE BELOW)
Press
and hold for at least 1 second, to display the information indicated in the table. Press
DESCRIPTION
00
Secondary fault internal code
01
Heating flow temperature (°F/°C)
02
Outdoor temperature (°F/°C)
03
Indirect Tank DHW temperature (boiler CH only)
Domestic hot water temperature (boiler with plate
04
exchanger)
05
Water pressure in heating system (PSI/bar)
06
Heating return temperature (°F/°C)
07
Thermo fuse status (000/001)
08
Not used

3.5 SHUTTING OFF THE BOILER

To turn off the boiler, disconnect the electric power supply. In the "Off" operating mode
remain powered and the frost protection function remains active.

3.6 FROST PROTECTION MODE

The electronic boiler management system includes a "frost protection" function for the heating system which, when delivery
temperature falls below 41°F (5°C), lights the burner until a delivery temperature of 86°F (30°C) is reached.
This function is only operative if the boiler is electrically powered and there is gas with normal system pressure and the flue is not
blocked.
PN 240012486 REV A [12/30/18]
respectively to adjust the CH and DHW flow temperature (if an indirect storage tank is fitted).
.
and heating flow temperature °F / °C.
indirectly adjusts room temperature (factory setting 68°F / 20°C).
and heating flow temperature °F / °C.
DESCRIPTION
09
Set-point Central Heating (°F/°C)
10/11
Manufacturing information
12
Flue sensor temperature (°F/°C)
13
Manufacturing information
14
Identification Open Therm communication
15
Manufacturing information
16
Manufacturing information
17
Fan speed ("i17"x100)
18
Manufacturing information
the boiler stays off but the electrical circuits