Bottom Heater; Circuit Board Holder; Programming Unit - Weller WQB 3000 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.4 Bottom heater

High-temperature ceramic radiation elements (long-wave infrared radiation, λ ≈ 2 – 10 µm)
Small preheating zone:
Large preheating zone:
Temperature control via thermocouple, integrated in centre radiator
Mesh cover plate to protect against contact
Bottom heater can be shifted along length of base table

6.5 Circuit board holder

Precision linear guide unit with two slides units for the clamping arms
Precision drive in x and y direction, adjustment range ± 10 mm, accuracy ± 0.05 mm
Adjustment range:
Width (max.):
Width (min.):
Length:

6.6 Programming unit

LCD display with background lighting
Key switch
Connection to the base unit via RS-232 interface
30 programmable program sets
Three process steps and subsequent cooling phase. The following parameters can be programmed
separately for each process step:
Temperature of bottom heater: 50 °C - 400 °C
Temperature of top heater:
Air flow:
Process time:
additional:
Cooling time:
Size of bottom heater:
Special features:
Adjustable fan speed
Standby temperature for top and bottom heater
Temperature offset for top and bottom heater
Two different lock types
°C and °F display
Teach-In mode for determining temperature profile
33
400 watts
approx. 125 x 125 mm
1600 watts
approx. 270 x 270 mm
495 mm
30 mm
unlimited
50 °C - 400 °C
10 % - 100 % (5 l/min. - 50 l/min.)
0 sec. - 999 sec.
0 sec. - 999 sec.
small – large
Cooper Tools GmbH, Carl-Benz-Str. 2, 74354 Besigheim, P.O. Box 1351
2
2
Germany, Tel: (07143) 580-0, Fax: (07143) 580108

Publicité