Important: For the process sequence of the automatic Teach-In, the measured temperatures of Sensor1
are definitive
The limiting temperatures of Sensor 1 can now be changed with the arrow keys ∧ ∨ and confirmed with the
SELECT key.
A U T O M A T I C
> S T E P 1 - E N D
S T E P 2 - E N D
S T E P 3 - E N D
The soldering process can be started with the pre-set limiting temperatures using the START key.
The program steps will continue automatically after the limiting temperatures have been reached.
The subsequent cooling time will be accepted by the selected program location (which was loaded at the
beginning).
S T E P
1
- - - - - - - - - - - - - - - - - - - -
→ S E N S O R
T I M E
P A S S E D
(It is possible to advance the process steps manually by pressing the Start key during the automatic Teach-
In mode sequence. The Teach-In process can be interrupted at any time with the Stop key.)
The soldering process is concluded after the cooling time sequence. The three times, as determined, are
now in the temporary memory of the program location. The programming unit shows the Status display.
The process times can be saved by pressing the program key twice as described in Section 3.5, Saving and
Loading.
Manual Teach-In
Before the Teach-In mode is activated, the program location must be determined for which the new
temperature profile is to be created. If no suitable program is available, the standard program can be used.
See the procedure described in Section 3.5, Saving and Loading.
The programming unit shows the Status display or is in the Program mode.
Pressing the SELECT key and also pressing the START key will cause the menu for the Teach-in mode to
appear on the programming unit display.
T E A C H - I N
> M A N U A L
A U T O M A T I C
The arrow keys ∧ ∨ are used to select the manual or automatic Teach-in Mode. The SELECT key is used to
call up the desired menu. The program sequence will start immediately.
T E A C H - I N
T E A C H
1
M O D E
M O D E
M O D E
29
Teach-In Mode
1 1 0 ° C
1 7 0 ° C
Input of target temperatures
2 2 0 ° C
I N
0 5 6 ° C
0 0 6
s
P 0 1
Cooper Tools GmbH, Carl-Benz-Str. 2, 74354 Besigheim, P.O. Box 1351
Germany, Tel: (07143) 580-0, Fax: (07143) 580108
Teach-In Mode
Program sequence with display
of elapsed process time
Teach-In Mode with external
Sensor 1