EOX
11110111
function
Effect Program LCD Back Color
■ 2.8.2.17 Parameter request (Function call: LCD Back
Color)
• Format
STATUS
11110000
ID No.
01000011
SUB STATUS
0011nnnn
GROUP ID
00011110
MODEL ID
00001001
ADDRESS
00010100
01100100
0mmmmmmm
0mmmmmmm
EOX
11110111
For the function and number, refer to the table in "2.8.2.16 Parameter
change (Function call: LCD Back Color)."
■ 2.8.2.18 Parameter change (Remote Meter)
When the SPX2000 receives a Parameter Request (Remote Meter) mes-
sage, it will transmit this message. The content is data for the specified
meter. This is transmitted at 50 msec intervals for ten seconds. If you
want meter data to continue being transmitted, you must transmit a
Request message at intervals of less than ten seconds. However if the port
is being used for other communication, transmission of meter data may
be interrupted.
The device number used when transmitting meter data will be the MIDI
channel of the SPX2000. If the MIDI channel is OMNI, the device num-
ber will be 1.
When the SPX2000 receives a Request message with an Address UL =
0x7F, transmission of all meter data will be halted immediately. Transmis-
sion will also stop if the power is turned off and on again while transmit-
ting meter data, or if the MIDI port setting is changed.
• Format
STATUS
11110000
ID No.
01000011
SUB STATUS
0001nnnn
GROUP ID
00011110
MODEL ID
00001001
ADDRESS
00100001
0mmmmmmm mm ADDRESS UL
0mmmmmmm mm ADDRESS LU
0mmmmmmm mm ADDRESS LL
DATA
0ddddddd dd Data1 H
0ddddddd dd Data1 L
:
EOX
11110111 F7 End of exclusive
■ 2.8.2.19 Parameter request (Remote Meter)
• Format
STATUS
11110000
ID No.
01000011
SUB STATUS
0011nnnn
GROUP ID
00011110 1E MODEL ID (signal processor)
MODEL ID
00001001 09 SPX2000
ADDRESS
00100001 21 Remote meter
0mmmmmmm mm ADDRESS UL
0mmmmmmm mm ADDRESS LU
0mmmmmmm mm ADDRESS LL
0ccccccc ch Count H
0ccccccc cl Count L
EOX
11110111 F7 End of exclusive
94
SPX2000—Mode d'emploi
F7
End of exclusive
number
1-221(1-122:res-
0x64
ponse only)
F0
System exclusive message
43
Manufacture's ID number
(YAMAHA)
3n
n=0-15 (Device number=Device
No-1)
1E
MODEL ID (signal processor)
09
SPX2000
14
Function call
64
LCD Back Color
mh
number High
ml
number Low
F7
End of exclusive
F0
System exclusive message
43
Manufacture's ID number
(YAMAHA)
1n
n=0-15 (Device number=Device
No-1)
1E
MODEL ID (signal processor)
09
SPX2000
21
Remote meter
:
F0
System exclusive message
43
Manufacture's ID number
(YAMAHA)
3n
n=0-15 (Device number=Device
No-1)