OPT 8 Selection of GARAGE LIGHT ACTIVATION times
(from min. 1 minute to max. 15 minutes)
procedure to follow starting with the gate closed
Follow the above procedure to select and confirm the number of
ENTER
OPT 9 Selection of GARAGE LIGHT ACTIVATION
for sending pulses to an external timer
(fixed 1 second time)
ENTER
WARNING: OPTIONS 8 AND 9 CANNOT BE USED TOGETHER.
?
ESC
AUTOMATIC CLOSING PROCEDURE
OPTION
enabled
ENTER
ESC
Activation of standby time for automatic closing, with the time interval
set in the timer programming.
Activation of automatic closing time, also if system is blocked at mid-
stroke (if option 1 is enabled)
Inhibition of automatic closing, when the Stop pushbutton is pressed
with the barrier open (if option 1 is enabled)
Automatic closing activation of pedestrian passage (it does not
operate when access control system is enabled)
NOTE ON TIME DELAY PRIOR TO AUTOMATIC CLOSING:
When the gate is open, if anyone passes in front of the photo-electric cells, the
automatic closing timer restarts the count from zero.
Access control activation (de-activates options 1-2-3-4). Automatic
closing takes place once the passage of a vehicle has been detected (The
activation of this function de-activates the pedestrian passage function)
NOTES FOR CORRECT OPERATION OF ACCESS CONTROL SYSTEM
Input "E" (N.C.) can be connected to a magnetic sensor positioned in the
immediate vicinity of the system, to indicate the presence of a vehicle.
Input "K" and input "RADIO" controls are enabled when a vehicle is present,
while input "9" remains permanently enabled.
If this control is not required, jumper input "E" with terminal "8".
Inputs "10" and "B" (N.C.) must be connected to a pair of photocells positioned
in alignment with the vehicle transit line to guarantee safety and enable closing.
ACCESS CONTROL OPERATION MODE
When a vehicle is present on the magnetic sensor, barrier opening can be
activated by means of pushbutton "K" or a "RADIO" pulse. The control remains
activated until the vehicle engages the photocells on the vehicle transit line.
On second after transit, closing is activated immediately protected by the same
photocell which if engaged a second time inverts the direction or movement,
while maintaining transit in the memory. On completion of opening, the barrier
closes again.
A standby time can be set before automatic closing (FUNCTION 2, OPTION 1).
This time must be greater than the time taken by the vehicle to complete transit.
If no transit occurs during this time interval, the barrier closes.
minutes required with the garage light
on. Numbers from 0 to 15 will flash on
the display.
FUNCtion 2
OPTION
inhibited
ENTER
?
ESC
PHOTO-ELECTRIC CELLS
OPT 1: Photo-electric cell function selection
ENTER
ESC
The photo-electric cells intervene both during the opening and closing
manoeuvres as required by Italian standard UNI 8612 (1989).
The photo-electric cells only intervene during closing manoeuvres.
NOTE ON THE OPERATION OF THE PHOTO-ELECTRIC CELLS:
If the photo-electric cells (contact 10) detect an obstacle during the opening or
closing manoeuvre, the count of the memorised opening time is suspended (the
motors stop). After the obstacle has been removed (the contact returns as
BREAK CONTACT), the motors start (the timer count also restarts) the opening
manoeuvre for the remaining opening time (if the opening manoeuvre was
suspended) or for the amount of closing time passed (of the suspension
occurred during closing).
When the photo-electric cells are interrupted momentarily by the passage of a
pedestrian , the automation system interrupts the manoeuvre for the minimum
pause time of 2 seconds.
In the case of a photo-electric cell malfunction, if the gate manoeuvre command
has been given, the flashing light will not operate and the motors will not start.
N.B.: In the case of two or more pairs of photo-electric cells, connect the power
feed A*-A in parallel to all the transmitters and receivers, and the terminals 8-10
in series (see Figure 1).
ESC
230V FLASHING LIGHT
ENTER
ESC
The flashing light is fed intermittently (use flashing light without board
Code ACG7050)
The flashing light is fed continuously (use flashing light with board
Code ACG7010)
The flashing light and the motor are fed simultaneously
The flashing light starts 3 seconds before the motor (pre-flashing)
Connect the flashing light to terminals L-L. (230 Vac)
If the safety devices intervene during manoeuvring, the light will still continue to
flash.
?
ESC
ELECTRIC LOCK RELEASE OPERATION
ENTER
ESC
pag. 17 di 24
FUNCtion 3
ENTER
FUNCtion 4
ENTER
FUNCtion 5
(Duration 1.5 sec.)
ENTER