Error, stop button contact is open
Error, photo-electric cell contact is open
First gate leaf M1 is open, if the plant is at the limit switch
Gate leafs M1 and M2 are closed, the plant is at the limit switch (press
TURN to display the limit switch contact of the second gate leaf M2)
Gate closed with time function, no limit switches
Error, second gate leaf M2 opening limit switch contact is open
Error, second gate leaf M2 closing limit switch contact is open
CONTROL U U NIT C C ONFIGURATION
The control unit has two displays (FUNCtions and OPTions)
and 3 control buttons (ENTER for confirmation, ESC to exit and TURN to
display the various FUNCtions and OPTions).
- To display the functions menu
press the ESC and TURN buttons simultaneously.
The following messages will be displayed
PHASE SEQUENCE:
- Use the TURN button to select the required FUNCtion (FUNCtions F, 1, ..., 9,
A).
- Press the ENTER button to display the OPTions of the FUNCtions selected
(the decimal point of the FUNCtions display will disappear)
- Use the TURN button to memorise the displayed OPTion, the display will move
to the next OPTion.
- During this phase, pressing ENTER will activate or de-activate the OPTions.
- Press the ESC button to return to the FUNCtion selection (the decimal point of
the FUNCtion display will re-appear)
- To exit the programming, press the ESC button a second time.
EXPLANATORY DIAGRAM:
ENTER
ESC
ESC
ESC
TURN
The control unit is already configured for automatic operation of a two-leaf
gate system with 2 single-phase motors, no limit switch detectors, with
electric lock, general and pedestrian automatic closing.
FUNZ OPZ
ENTER
ESC TURN
OPTION SELECTION RANGE
ENTER
TURN
ENTER
SYSTEM CONFIGURATION PROGRAMMING
ESC to return to function menu
ENTER
1 motor
sliding (door)
w/out limit switch
-
-
-
-
without
electric lock
-
The A FUNCtion, OPTion b is specifically of the AQM11.
FUNCTION CHECK
Once all the connections have been made as shown in the diagram, it is good
practice to follow this procedure to prevent possible incorrect manoeuvring:
ENTER
- Place the automation system in stand-by (with ratio motors released and limit
switch detectors free).
- Keep the open button/selector (8-9) pressed and check that the motor(s)
opens the gate (reverse wires V and W, leaving wire U unchanged, of the motor
which rotates in the wrong direction).
- Keep the close button/selector pressed (8-11) and check that the first leaf is
closed by motor M2 of the second leaf.
- Check the correct position of the limit switches.
- Fully close the gate and switch to time programming.
ESC
OPT 1 - OPERATING TIME ADJUSTMENT
Programming procedure:
ENTER
NOTE: The safety devices are also active during the time programming
procedure, therefore keep clear of the system. If the safety devices
intervene during manoeuvring while adjusting the times, the system will
stop. To return to the FUNCtion mode F, re-close the plant, return to FUNCtion
1 OPTion 1 and repeat the time programming procedure).
PHASES:
SYSTEM WITH 2 MOTORS AND NO LIMIT SWITCH DETECTION
procedure to follow starting with the gate closed
To start the timing, press one of the K/9/turn/Remote control buttons.
1st Pulse: first leaf M1 opening control pulse and counter start
FUNCtion A
ENTER
2 motors
swing (door)
with limit switch
single-phase
three-phase
BT 12/24Vcc
double speed
with electric lock
Idro R. (add 7s
to closing time)
FUNCtion F
FUNCtion 1
TIME PROGRAMMING
ENTER
pag. 15 di 24