Battery type

Batterie
Blei-Flüssig
Blei-Gel
Blei-AGM
It must be ensured that the correct battery type is set in order
to achieve a long battery life.
No guarantee for damage caused by incorrectly adjust-
ed battery type.
In case of doubt ask an expert.

Message

System messages e.g. for displaying faults.
Meldung
Gas prüfen
F001
To reset (fault reset)
Remedy or
Acknowledge the fault or
Restart the fuel cell system

Information

Information about operating data and service
Information
Betriebsdaten
Betriebsdaten

Service

Service

Operating data

Betriebsdaten
Betriebstunden
800 h
Service in
200 h
200000 Wh
Abgabe
Service
Service
Softwareversion: xxxx
Kontakt:
Truma Gerätetechnik GmbH & Co KG
Wernher-von-Braun-Straße 12
85640 Putzbrunn
Telefon
+49 (0)89 4617-2142
Telefax
+49 (0)89 4617-2159
26
Choose battery type
= Lead liquid electrolyte
= Lead gel battery
= Lead AGM
= Press the button to
request message detail
= Error number – see
troubleshooting guide
= Fault acknowledgement
= Operating hours
= Operating hours until the
next service
= Output to date in Wh
= Software version
= Service address

FrostControl for internal water container

FrostControl is a currentless safety/drain valve. When there is
a danger of frost, it automatically drains the contents of the
boiler through a drainage muff.
n
m
k = rotary switch position "Operation"
m = push button position "Closed"
n = push button position "Drain"
o = drainage muff (led outside through floor of vehicle)

Closing the drain valve

Check if the rotary switch is set to "Operation" (position k),
meaning that it is parallel to the water connection and
engaged.
Close the drain valve by activating the push button. The push
button must engage in position (m) "closed".
Only when the temperature around the drain valve is over
around 7 °C can it to be closed manually with the press button
("m" position) and the boiler filled.

Automatic opening of the drain valve

If the temperature around the drain valve is below about 3 °C,
it will open automatically and the push button will disengage
(outward movement) ("n" position). The water from the boiler
will be released through the drainage muff (o).

Manual opening of the drain valve

Turn the rotary switch by 180° until it engages, whereby the
push button moves out (position n). The water in the boiler
drains out through the drainage muff (o).
The FrostControl drainage muff (o) must be free of contamina-
tion (slush, ice, leaves, etc.) at all times so the water can drain
out easily! There shall be no claims under guarantee for
damage caused by frost!

Maintenance

Only original Truma parts may be used for maintenance and
repair work!
The service interval is 1000 operating hours. 50 operating
hours later, the device will no longer be operational.
The particle filter / combination filter must be changed several
times within a maintenance interval if the supply air is ex-
tremely soiled.
The maintenance must be carried out by trained experts, and
must be noted in the maintenance log.
Deionised water must occasionally be added by the end con-
sumer, which is indicated on the Touch Panel.