Fichier d'exemple modem_z.cfg

#
# COMPONENT_NAME: (ESPSETUP) ENTRY SERVICE PROCESSOR SETUP Z
#
# FUNCTIONS: Modem configuration file for many early Hayes* compatible modems.
# This example uses the ATZ reset command to choose the factory defaults.
# This setup will work for many modems, but it is required for early vintage
# modems which respond to neither the ATZ0 reset command nor the extended (&)
# commands. Refer to your modem manual.
#
# * Trademark of Hayes Microcomputer Products, Inc.
#
# (C) COPYRIGHT International Business Machines Corp. 1996
# All Rights Reserved
# Licensed Materials – Property of IBM
#
# US Government Users Restricted Rights – Use, duplication or
# disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
#
#
# If the modem has configuration switches, they should be set to the
# factory default settings.
ICDelay 1
DefaultTO 10
CallDelay 120
# AT Attention Code
# Z Reset to factory defaults Q0 Turn on responses
# E0 Turn echo off
# V0 Use numeric responses
# +++ Escape to command mode S0=2 Answer on second ring
# H0 Hang–up
#
no op to maintain program synchronization
#
when modem may/will echo the commands.
#
# %N Call–Out phone number %P Paging phone number
# %S Modem speed (available to users)
#
# Following are common responses from a wide range of modems:
# 16, 15, 12, 10, 5 and 1 are connection responses. Add others as required.
# 7=busy; 6=no dial tone; 4=error; 3=no carrier; 2=ring; 0=OK
#
# PROGRAMMING NOTE: No blanks between double quote marks (").
condout: send "ATZQ0T\r"
ignore "0\r" or "OK\r\n" timeout 2
send "ATE0T\r"
expect "0\r" or "OK\r\n" timeout 2
send "ATQ0V0T\r"
expect "0\r" timeout 2
send "ATS0=0\r"
expect "0\r" timeout 2
done
connect: send "ATDT%N\r"
expect "16\r" or "15\r" or "14\r" or "12\r" or "10\r" or "5\r" or "1\r" busy "7\r"
, Inserts delay in dialing commands
Q1 Turn off responses
S0=0 Automatic answer inhibit
T = Tone mode. When used as T\r, it is a
# Reset to factory defaults.
# Ignore modem response.
# Initialize modem: Echo OFF,
# Enable responses (Numeric),
# Limit response codes.
# Confirm commands successful.
# Set AutoAnswer OFF
# Confirm command successful.
# Tone dialing command.
# %N from Call Home setup.
# Expect a connection response.