English
5
Commissioning
5.7
Configuring the external dosage connector
The service technician configures the transfer strip in the Dosing menu and, in doing so, determines the type of dosing device.
Detergent dosing device
1
Item
Name
1
Reset to default setting
2
For dosing devices not from Miele:
– While machine fills
– Parallel to the solenoid valve
For Miele dosing devices:
– Peristaltic pump
– Fluidos
– MPI/PPX
3
Save settings
Rinse aid dosing device
1
Item
Name
1
Reset to default setting
2
For dosing devices not from Miele:
– Parallel to the rinse pump
– Parallel to the solenoid valve
For Miele dosing devices:
– Peristaltic pump
– Fluidos
– MPI/PPX
3
Save settings
80
2
3
2
3
|
12020320/01; 2022-01
Note
When setting the "peristaltic pump", be sure also to set
the output to ml/mm.
Set the dosing amount in the Dosing menu.
Note
When setting the "peristaltic pump", be sure also to set
the output to ml/mm.
Set the dosing amount in the Dosing menu.
|
Operating instructions PTD 901