Commissioning
Connecting the mains cable
Note: Select the correct cross section and number of wires in the mains cable to suit the on-site voltage and fuse protection.
Ø
Remove the front cover.
Ø
Insert the mains cable (1) at the rear of the machine.
Ø
Pull the mains cable (1) out at the front and guide it to the left.
Ø
Strip the wire end of the mains cable and attach ferrules.
Ø
Connect the mains cable wires (3) according to the connection diagram } 77 and close the quick release connectors (2).
Ø
If necessary, connect the bridges (6) according to the connection diagram } 77 (7) and press in firmly using a screwdriver.
Ø
Connect the green-yellow wire on the distributor to the earth wires (4).
Ø
Fasten the mains cable to the strain relief on the mounting plate using a cable tie (5).
1
Establishing equipotential bonding
1
76
4
2 3
|
12020320/01; 2022-01
1
5
Ø
Connect the warewasher to the on-site equipotential bonding
system.
Ø
Position of the connecting screw (1) see drawing.
|
6
7
Operating instructions PTD 901