Commissioning
Requirements for on-site installation
Inlet water connection
Location
Construction
Inlet water temperature
Water quality
Water hardness
Water flow pressure
Max. inlet pressure (back pres-
sure)
Flow rate
Waste water connection
Location
Dimensions
74
approx. 500 mm above finished floor; to the right of the machine
Isolation valve with G ¾" external thread
PTD 901,
max. 60 °C
PTD 901 LIFT
PTD 901 ECO,
max. 20 °C
PTD 901 LIFT ECO
Microbiologically, fresh water must be of drinking water quality
Machines without integrated softener
PTD 901,
≤ 3 °dH (3.8 °e / 5.34 °TH / 0.54 mmol/l)
PTD 901 LIFT
Recommended, so that the warewasher
does not scale up.
PTD 901 ECO,
≤ 3 °dH (3.8 °e / 5.34 °TH / 0.54 mmol/l)
PTD 901 LIFT ECO
PTD 901,
100 kPa (1.0 bar)
PTD 901 LIFT
PTD 901 ECO,
150 kPa (1.5 bar)
PTD 901 LIFT ECO
1000 kPa (10.0 bar)
min. 4 l/min
approx. 650 mm above finished floor; left or right of the machine
Ø 40 mm or 50 mm with trap
|
12020320/01; 2022-01
Machines with integrated softener
53.4 °TH / 5.35 mmol/l)
35.6 °TH / 3.58 mmol/l)
|
Operating instructions PTD 901
≤ 31 °dH (37.6 °e /
≤ 20 °dH (25.1 °e /