Value
State
Electronic brake activated.
The garage light remains
on.
Vacation lock is activated.
Door does not open.
Wicket door contact test
failed.
7.1

Restoring the factory settings

1. Press the OPEN (B) and CLOSE (C) buttons at the same time.
B
C
Fig. 17: Factory settings
2. Press both buttons for approximately 3  seconds while pulling out the mains
plug from the mains socket and while reinserting the mains plug again.
7.2

Cycle counter

The cycle counter stores the number of OPEN/CLOSE actions powered by the
drive. To read the meter, hold the button (C) at the drive head for 3 seconds until
you see a figure.
The digital display shows the numbers starting from the highest to the lowest
decimal place consecutively. At the end, a horizontal line appears on the display,
for example: 3456 movements, 3 4 5 6 –.
70 - EN
Diagnosis / remedy
The operator is pulled from upper end position. Check the
door and the springs. Set a lower upper end position.
The side switch for SafeControl/Signal 112 is active. A
reset is required.
Check the cables and clamping connections of the wicket
door contact.