Lubrication; Grounding Instructions - Speedaire 3JR85 Manuel D'utilisation

Compresseurs d'air portatifs, série en fonte
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Speedaire Operating Instructions
Cast Iron Series
Assembly (Continued)
OIL DRAIN ExTENSION
Some models include an oil drain
extension and cap (found with the
owner's manual). Install the oil drain
extension and cap before adding oil to
the pump. To avoid oil leaks, it is highly
recommended to apply PTFE thread
sealant tape or paste type sealant to
the threads on each end of the oil drain
extension. Screw the cap onto one
end of the extension. Remove the oil
drain plug from the base of the pump
and install the oil drain extension (See
Figure 6).
Dipstick
Breather
Dipstick
Drain
Add Oil
Oil Sight Glass
Oil Drain Extension
Cap
Figure 6
NOTE: If your model is equipped with an
oil sight glass, add oil to the fill line (See
Figure 6).

LubRICATION

ThIS UNIT CONTAINS
NO OIL! Follow
lubrication instructions before
operating compressor.
Synthetic oil has proven to
provide superior lubrication and
is recommended for Speedaire air
compressors. Use 10W30 100%
synthetic oil such as Mobil 1 (Stock No.
4F743). Single viscosity, ISO100 (SAE 30)
non-detergent compressor oil such as
Mobil Rarus
(Stock No. 4ZF21), can also
®
be used. Both are available at your local
Grainger branch.
automotive oil which has shown to
increase carbon deposits on the valves,
resulting in more frequent service and
reduced life.
Model
3JR85, 4TW29
4B227, 4YN50
4B228
WIRING
Fill Line
Local electrical wiring codes differ from
area to area. Source wiring, plug and
protector must be rated for at least the
amperage and voltage indicated on your
motor nameplate, and meet all electrical
codes for this minimum. Use a slow blow
fuse type T or a circuit breaker.
Overheating, short-circuiting
and fire damage will result
from inadequate wiring.
NOTE: 120 volt, 15 amp units can be
operated on a 120 volt 15 amp circuit
under the following conditions:
1. No other electrical appliances or lights
are connected to the same branch
circuit.
2. Voltage supply is normal.
3. Circuit is equipped with a 15 amp
circuit breaker or a 15 amp slow blow
fuse type T (For Canada use Type D).
If the above conditions cannot be met
or if nuisance tripping of the current
protection device occurs, it may be
necessary to operate the compressor
from a 120 volt 20 amp circuit. Some
models convert to 240 volt operation,
see DUAL VOLTAGE MOTOR.

GROuNDING INSTRuCTIONS

Do not use
1. This product must be grounded.
petroleum based
In the event of an electric short
circuit, grounding reduces the risk
of electrical shock by providing an
escape wire for the electric current.
Unit is equipped with a cord that has
Oil Capacity
a grounding prong. It will fit one of
(approx.)
the common outlet types shown in
11 oz.
Figure 7. If plug will not fit in the
11 oz.
desired outlet, have the outlet
12 oz.
replaced by a qualified electrician.
Figure 7
grounding plug can result in a
risk of electrical shock.
NOTE: Do not use grounding
adapter.
2. If repair or replacement of the cord or
plug is necessary, do not connect the
grounding wire to either flat blade
terminal. The wire with insu
lation having an outer surface that is
green with or without yellow stripes is
the grounding wire.
5
Ground Pin
Ground Pin
120V
15A
120V
20A
Grounded Outlet
Grounded Outlet
Improper
use of
E
N
G
L
I
S
H
240V
15A
240V
20A
®

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

4tw294b2274yn504b228

Table des Matières