Troubleshooting
7.1
Fault messages and signal tones
All faults are indicated by a warning symbol, a fault ID and a beep. The beeping lasts
for 2 minutes and is repeated every 30 minutes until the error has been rectified.
If multiple faults occur, the display shows the last fault. The underlying faults are dis-
played after the last fault has been confirmed.
RMD 10.5T, RMD 10.5XT: Faults are indicated by a fault code with a warning
symbol (
) in the middle of the TFT display.
RMD 10.5, RMD 10.5X, RMD 10.5S, RMD 10.5XS: In the event of a fault, the LED
warning symbol (
ing to the fault.
WARNING type fault messages
All faults of the WARNING type are reset automatically once the fault has been
rectified.
RMD 10.5,
RMD 10.5T,
RMD 10.5X,
RMD 10.5XT
RMD 10.5S,
RMD 10.5XS
W01
W05
W06
W11
W10
+ beep
32
in the display lights up continuously and the LEDs flash accord-
)
Fault
Defective temperature
sensor in the refrigerator
compartment
AC power not connected or
AC voltage < 190 V
DC power not connected
DC overvoltage (> 16 V)
Tank stop mode: Gas
operation is blocked for
15 minutes.
Beep
The door is opened for more
than 2 minutes.
Solution
Contact an authorized customer
service.
Connect the refrigerator to AC or
select a different energy type, e.g.
gas or DC.
Connect the refrigerator to DC or
select a different energy type, e.g.
gas or AC.
Reduce the DC supply voltage.
Wait 15 minutes or switch to another
operating mode.
Close the door.