Fault
With DC operation: 
The refrigerator does not
work.
With gas operation: 
The refrigerator does not
work.
In automatic mode: 
The refrigerator is being
operated with gas
although it is connected
to the AC mains.
The refrigerator is not
adequately cooling.
EN
Possible cause
The fuse in the DC supply is
defective.
The vehicle fuse has blown.
The vehicle battery is discharged. Test the battery and charge it.
The ignition is not turned on.
The DC heating element is
defective.
The gas cylinder is empty.
The gas valve is closed.
Air is in the supply line.
The mains voltage is too low.
The ventilation around the
cooling unit is not sufficient.
The evaporator is iced up.
The temperature is set too high.
The ambient temperature is too
high.
Too much food was placed in the
refrigerator at once.
Too much warm food at once
was placed in the refrigerator.
The refrigerator has not been
operating for very long.
Troubleshooting
Suggested remedy
The fuse on the relay must be
replaced.
Contact an authorized customer
service.
Replace the vehicle fuse. (Please refer
to the operating manual of your
vehicle.)
Switch on the ignition.
Contact an authorized customer
service.
Replace the gas cylinder.
Twist the valve open.
Switch the refrigerator off and on
again. Repeat the procedure three or
four times if necessary.
If available, switch on the stove and
repeat the process with the refrigerator
if necessary.
The refrigerator changes to AC power
supply automatically as soon as the
mains voltage is sufficient again.
Check that the ventilation grill is not
obstructed.
Check whether the refrigerator door
closes properly. Make sure that the
refrigerator seal fits correctly and is not
damaged. Defrost the refrigerator.
Set a lower temperature.
Remove the ventilation grill for a while
so that warm air can escape quicker.
Remove an item of food.
Remove the warm food and leave it to
cool down before putting it in again.
Check the temperature again after four
or five hours.