Power supply .......................................................................................................12Vcc (10V-15V)
Consumption .........................................................................................................................1,0 mA
Consumption in DEEP SLEEP MODE ............................................................................. 0,3 mA
Consumption in STOP MODE .............................................................................................. 0 mA
Operating temperature ..........................................................................................- 25°C + 85°C
Sound level of siren ................................................................................................(1 mt.) 114 dB
Self-supply autonomy ...................................................................................................5 minutes
Remote controls ...................................72 million billion variable codes (lithium battery)
Sensitivity of internal movement sensor .....................................................1,5° per second
Frequency of Mycro remote control .....................................................................433.92 MHz
Frequency of CARD B9.5 .................................................................................................2.45 GHz
EMERGENCY 'OVERRIDE' CODE to reset immobilizer and alarm functions
Starter motor relay ......................................................................................................................10A
Direction indicator relay ....................................................................................................5A + 5A
Horn control .....................................................................................Negative electronic 300mA
Initial immunity phase ...............................................................................................26 seconds
Duration of alarm cycle ...............................................................................................26 seconds
Interval between alarm cycles .....................................................................................5 seconds
Passive arming delay ...................................................................................................50 seconds
STOP MODE delay ...................................................................................................................5 days
Intermittence of direction indicators ................................................0,4 sec. Off /0,4 sec. On
Contact alarm inputs ........................................................................................................10 cycles
Tilt sensor .............................................................................................................................10 cycles
Ignition sensing .................................................................................................................10 cycles