2. Inputs
INP A
Start input (depending on the input mode chosen)
INP B
Start/Stop or gate input (depending on the input
mode chosen)
SET/RESET input
Dynamic SET/RESET input. Linked in parallel to
the red RESET key. Resets the counter to the
predefined setting value.
3. Optocoupler output
On active counting the output alternates at a fre-
quency of 1 Hz between active and inactive.
4. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the
factory settings
4.1 Polarity of the inputs
npn: switching for 0 V
pnp: switching for +U
4.2 Switching on the 30 Hz filter (INP A, INP B)
30 Hz filter off
Start/Stop inputs not damped
30 Hz filter on
Start/Stop inputs damped for
use with me cha nical switches.
8
(optional)
B
4.3 Input mode
Start/Stop via Inp B. counting
while Inp B (Gate) not active or
open
Start/Stop via Inp B.
counting while Inp B (Gate) ac-
tive (High level with pnp; Low
level with npn)
Count Start/Stop via INP B
(LOW-HIGH edge with pnp;
HIGH-LOW edge with npn).
Every active edge changes the
counter status.
Count start via INP A, stop via
INP B. (LOW-HIGH edge with
pnp; HIGH-LOW edge with npn)

4.4 Operating mode

Time unit: seconds (accuracy
depending on position of the
decimal point*)
Time unit: minutes (accuracy
depending on position of the
decimal point*)
Time unit: hours (accuracy de-
pending on position of the dec-
imal point*)
Time units:
Hours:Minutes:Seconds (deci-
mal point setting is ignored)
*0, 0.1, 0.01, 0.001 means: time measurement in
0, 0.1, 0.01, 0.001 time units