4.5 Dividing factor
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places. „0" is not ac-
cepted!
4.6 Decimal point
The decimal point defines the
way of displaying the count val-
ues. It does not affect counting.
0
0.0
0.00
0.000
4.7 SET/RESET Mode
manual reset via the red
SET/RESET key and electri-
cal reset via the SET/RESET
input
no reset (red SET/RESET key
and SET/RESET input locked)
only electrical reset via the
SET/RESET input
only manual reset via the red
SET/RESET key
4.8 SET value
The device will be set to the set
point by pressing the red
SET/RESET key or activating
the SET/RESET input.
SET value -199999... 999999
(number of decimal places de-
pends on the decimal point op-
tion)
For programming the decimal point see 4.6
6
no decimal place
one decimal place
two decimal places
three decimal places
4.9 End of programming
The programming routine is re-
peated once more. The values
set until now can be checked
and modified.
The programming routine wil be
left and all values set will be
stored as new parameters.
Afterwards the device is ready
for operation.
Tachometer/Frequency meter CODIX 542
(CODIX 544: Operating mode frequency meter)
1. Description
• 6 digit frequency meter
• Red LED display, character height 14 mm
• Display range from 0 to 999 999
• Leading zeros suppression.
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• Value conversion and display in 1/s or 1/min
• With AC power supply: sensor supply
voltage 24 V DC ±15 %/100 mA
• Optional optocoupler output
2. Inputs
INP A
Dynamic count input.
3. Optocoupler output
Active at f=0. Can be used e.g. to activate a „No
operation" lamp.
4. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the
factory settings
(optional)