4.1 Polarity of the inputs
4.2 Switching on the 30 Hz filter (INP A, INP B)

4.3 Input mode

30 Hz filter off
Start/Stop inputs not
damped
30 Hz filter on
Start/Stop inputs damped
for use with mechanical
switches.
Start/Stop via Inp B.
counting while Inp B
(Gate) not active or open
Start/Stop via Inp B.
counting while Inp B (Gate)
active (High level with
pnp; Low level with npn)
Count Start/Stop via INP B
(LOW-HIGH edge with
pnp; HIGH-LOW edge
with npn). Every active
edge changes the counter
status.
Count start via INP A,
stop via INP B. (LOW-
HIGH edge with pnp;
HIGH-LOW edge with
npn)

4.4 Operating mode

*0, 0.1, 0.01, 0.001 means: time measurement in
0, 0.1, 0.01, 0.001 time units
4.5 Decimal point
4.6 SET/RESET mode
Time unit: seconds (accu-
racy depending on posi-
tion of the decimal point*)
Time unit: minutes (accu-
racy depending on posi-
tion of the decimal point*)
Time unit: hours (accura-
cy depending on position
of the decimal point*)
Time units:
Hours:Minutes:Seconds
(decimal point setting is
ignored)
The decimal point defines
the resolution of the pro-
grammed time unit.
0
1
0.0
1/10
(0,1)
0.00
1/100 (0,01)
0.000 1/1000 (0,001)
manual reset via the red
SET/RESET key and
electrical reset via the
SET/RESET input
no reset (red SET/RESET
key and SET/RESET
input locked)
only electrical reset via
the SET/RESET input
only manual reset via the
red SET/RESET key