Setup Key
3
Short Press.
for saving and recalling the working points that may
be changed by the operator: Memory
Long Press.
for saving the working points that may be changed
by the operator and recalling the synergic programs :
Program
Left Display
4
It views the values of the welding parameters.
4A
Selection Key
for selecting the following welding parameters:
MIG MAN – Wire Speed m/min 1-25, inch/min
39-974
MIG SYN – Amp, Wire Speed, thickness 0,6-
25 mm
MMA/STICK – Amp
TIG – Amp
Amperes LED
4B
lights up when the welding current parameter is selected.
Wire Speed LED
4C
lights up when the wire speed parameter is selected.
Thickness LED
4D
lights up when the thickness parameter is selected.
Right Display
5
views the welding parameters values.
Selection Key
5A
for selecting the following welding parameters:
MIG MAN – Voltage
MIG SYN Voltage, Balance
MMA/STICK – Hot Start
5B
LED V (Volts)
lights up when the welding voltage parameter is selected.
5C
LED Balance
lights up when the balance parameter is selected.
5D
LED P
lights up when the other parameters need to be
selected and adjusted, i.e. Hot Start in MMA/STICK,
and Memory and Program in MIG SYN
Top Center Regulation Knob
6
for adjusting the following welding parameters & values:
MIG MAN - MIG SYN - Tiempo de punteado
MMA/STICK - Arc Force
7
Bottom Center Regulation Knob
for adjusting the following welding parameters & values:
MIG MAN - Inductance
MIG SYN - Dynamics -10 / +10
Left Regulation Knob
8
for adjusting the following welding parameters &
values:
MIG MAN - Wire Speed m/min 1-25, inch/min
39-974
MIG SYN Amp, Wire Speed, thickness 0,6-25
mm
MMA/STICK - Amp
TIG - Amp
Right Regulation Knob
9
for adjusting the following welding parameters &
values:
MIG MAN – Voltage
MIG SYN – Voltage, Balance
MMA/STICK – Hot Start
10
Green LED
lights up when unit is correctly powered.
11
Alarm LED
lights up if the power source overheats (e.g. because
the duty cycle has been exceeded) or if there is a
problem on the water cooling. For more information
on this, see the "Troubleshooting" section.
LED VRD
12
lights up in case of inverter off, without output voltage.
Red Alarm LED
13
lights up because of Over Voltage, Phase Loss, Max
I.out, Max P .out or if a generic problem occurrs.
Left Display
14
views the welding parameters values.
Right Display
15
views the welding parameters values.
Mode Key
16
for selecting the following welding processes:
MIG/CV- MMA/STICK - TIG - GOUGING
Selection Key
17
for selecting the following welding parameters :
Hot Start and Arc Force in MMA/STICK wi-
thout wire feeder connected
Inductance in CV (constant voltage)
Regulation Knob
18
for adjusting the welding current (Amperes) and the
welding voltage (Volts).
19
BBT & Motor Slope Regulation Knobs
for setting the Burn Back Time and the Slope of the motor
in MIG/MAG. Note: knobs are located in the wire spool
compartment close to the wire feeding motor.
Test Gas and Wire Feed buttons
20
located in the wire spool compartment close to the wire
feeding motor
EN-11