08 - TROUBLESHOOTING

PROBLEM
Device not working
Not enough dehumidifi-
cation
Total operating time
reset
Error-Codes
URSACHE
No power
Error-Code
Insufficient operating
time
Filter blocked/dirty
Ambient temperature to
low
Waterhose blocked
The display cannot go
beyond a certain hour
and has to reset.
E1:
Thermostat error
E2:
Hygrostat error
E3:
Compressor / Co-
olingsystem error
E4:
Pump error
LÖSUNG
Check the cable, socket
and power fuses.
Check the code
Allow the device to
operate longer.
Clean the filter
Heat up the room
Check the hose and its
positioning
Write down the opera-
ting time on the device
or in the manual.
Contact your supplier
or a certified technician
Check the hose and its
positioning or contact
your supplier or a cer-
tified technician
EN